A position-sensitive scintillation detector for low-energy gamma-rays

Abstract Precise evaluation of a gamma-ray’s interaction position in scintillator detectors is important for their application in medical and industrial imaging. Two approaches can be pursued in achieving this goal: pixelated detectors or monolithic detectors coupled to pixelated readouts. Here, we present the design of a thin monolithic position-sensitive detector for low-energy gamma-rays. Two distinct position-evaluation methods were developed and assessed in terms of accuracy, precision, and imaging capabilities. An analytical model based on a curve-fitting procedure established a performance baseline. A neural network model showed superior performance, offering notable improvements in both accuracy and precision. Qualitative evaluation of the imaging results provided insights into the inherent advantages and limitations of both models. The results demonstrate the ability of a thin monolithic scintillator detector to generate images that significantly surpass the resolution of the readout array for low-energy gamma-ray imaging.

Authors

Institutions

Publication Details

Journal
EPJ Techniques and Instrumentation
Published
2026-02-03
DOI
https://doi.org/10.1140/epjti/s40485-026-00120-2
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A position-sensitive scintillation detector for low-energy gamma-rays

Gabriel Valter Turturica, Bogdan Temelie, Violeta Iancu
EPJ Techniques and Instrumentation
Radiation Detection and Scintillator Technologies
article

A position-sensitive scintillation detector for low-energy gamma-rays

Gabriel Valter Turturica, Bogdan Temelie, Violeta Iancu
article en

Abstract

Abstract Precise evaluation of a gamma-ray’s interaction position in scintillator detectors is important for their application in medical and industrial imaging. Two approaches can be pursued in achieving this goal: pixelated detectors or monolithic detectors coupled to pixelated readouts. Here, we present the design of a thin monolithic position-sensitive detector for low-energy gamma-rays. Two distinct position-evaluation methods were developed and assessed in terms of accuracy, precision, and imaging capabilities. An analytical model based on a curve-fitting procedure established a performance baseline. A neural network model showed superior performance, offering notable improvements in both accuracy and precision. Qualitative evaluation of the imaging results provided insights into the inherent advantages and limitations of both models. The results demonstrate the ability of a thin monolithic scintillator detector to generate images that significantly surpass the resolution of the readout array for low-energy gamma-ray imaging.

EPJ Techniques and InstrumentationVol. 13(1)
Extreme Light Infrastructure - Nuclear Physics (RO)
Affordable and clean energy
Openalex Percentile: Top 69%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.