Regional ventilation imaging in normal and bronchoconstricted <i>in vivo</i> rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging

<i>Objective.</i>To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in<i>in vivo</i>rabbit lungs.<i>Approach.</i>Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml<sup>-1</sup>). A tissue-based correction was used to isolate the xenon concentration (<i>C</i><sub>Xe</sub>) in the gas phase of the xenon density images. The resultant<i>C</i><sub>Xe</sub>images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation (sV˙in min<sup>-1</sup>). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout.<i>Main results.</i>MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%,<i>p =</i>0.026. The VDs at baseline did not reveal a reduced ventilation efficiency (sV˙VD:8.4 ± 2.7 min<sup>-1</sup>), compared to non-VD areas (sV˙non-VD:7.0 ± 3.1 min<sup>-1</sup>),<i>p =</i>0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency (sV˙VD:4.9 ± 2.3 min<sup>-1</sup>), compared to non-VD areas (sV˙non-VD: 6.4 ± 2.3 min<sup>-1</sup>),<i>p =</i>0.004<i>. Significance.</i>Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological<i>in vivo</i>rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-02-03
DOI
https://doi.org/10.1088/1361-6560/ae4164
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Regional ventilation imaging in normal and bronchoconstricted in vivo rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging

Sylvia Verbanck, Gert Van Gompel, Johan De Mey, Nico Buls et al.
Physics in Medicine and Biology
Atomic and Subatomic Physics Research
article

Regional ventilation imaging in normal and bronchoconstricted in vivo rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging

Sylvia Verbanck, Gert Van Gompel, Johan De Mey, Nico Buls, Sam Bayat, Emma Verelst
article en

Abstract

<i>Objective.</i>To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in<i>in vivo</i>rabbit lungs.<i>Approach.</i>Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml<sup>-1</sup>). A tissue-based correction was used to isolate the xenon concentration (<i>C</i><sub>Xe</sub>) in the gas phase of the xenon density images. The resultant<i>C</i><sub>Xe</sub>images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation (sV˙in min<sup>-1</sup>). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout.<i>Main results.</i>MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%,<i>p =</i>0.026. The VDs at baseline did not reveal a reduced ventilation efficiency (sV˙VD:8.4 ± 2.7 min<sup>-1</sup>), compared to non-VD areas (sV˙non-VD:7.0 ± 3.1 min<sup>-1</sup>),<i>p =</i>0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency (sV˙VD:4.9 ± 2.3 min<sup>-1</sup>), compared to non-VD areas (sV˙non-VD: 6.4 ± 2.3 min<sup>-1</sup>),<i>p =</i>0.004<i>. Significance.</i>Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological<i>in vivo</i>rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.

Physics in Medicine and BiologyVol. 71(3)
Vrije Universiteit Brussel (BE), Inserm (FR), Grenoble Institute of Neurosciences (FR), Université Grenoble Alpes (FR)
Fonds Wetenschappelijk Onderzoek, Vlaamse regering
Affordable and clean energy
Openalex Percentile: Top 67%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.