Posterior Skin Dose Considerations for Rectal Cancer Treatment with Volumetric Modulated Arc Therapy in the Supine Orientation

Background: One method for the radiation therapy of rectal cancer is to set patients supine and treat them with volumetric modulated arc therapy (VMAT). The posterior skin dose is of concern due to undesirable bolusing from mounting surfaces the patient lays upon, namely the carbon fiber couch (CFC). The posterior skin dose may be mitigated by positioning the patient on top of a low-density material that separates the patient from the CFC. Purpose: Our objective was to determine the reduction in the posterior surface dose when a mattress or foam board is used to prop the patient away from the CFC. Materials and Methods: Three clinical rectal cancer patient VMAT plans were selected. A solid water phantom with optically stimulated luminescence dosimeters (OSLDs) placed at the posterior surface was mounted using three setups: directly on the CFC, with a mattress on the CFC, and with a 10 cm thick foam board on the CFC. The three VMAT plans were delivered to this phantom, with OSLDs measuring the posterior surface dose with each setup. In the treatment planning system (TPS), the CFC only, mattress, and foam board setups were simulated on the patient’s anatomy with posterior surface doses reported. Results: The OSLD measurements in the phantom showed that the mattress reduced the posterior surface dose on average by 1.3%, and the foam board reduced the dose by 8.3%. The TPS estimates demonstrated that, on average, the mattress reduced the surface dose by 15.8%, and the foam board reduced the dose by 33.0%. It is likely that the TPS had limitations accurately modeling the surface dose, so OSLD measurements were closer to clinical reality. Conclusions: The mattress does not reduce the posterior skin dose enough to warrant its use as a skin sparing device. The CFC produces a bolusing effect that can be reduced by separating the patient from the CFC with a 10 cm thick foam board.

Authors

Institutions

Publication Details

Journal
Radiation
Published
2026-02-03
DOI
https://doi.org/10.3390/radiation6010005
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Posterior Skin Dose Considerations for Rectal Cancer Treatment with Volumetric Modulated Arc Therapy in the Supine Orientation

Aliaksandr Karotki, Anthony Kim
Radiation
Advanced Radiotherapy Techniques
article

Posterior Skin Dose Considerations for Rectal Cancer Treatment with Volumetric Modulated Arc Therapy in the Supine Orientation

Aliaksandr Karotki, Anthony Kim
article en

Abstract

Background: One method for the radiation therapy of rectal cancer is to set patients supine and treat them with volumetric modulated arc therapy (VMAT). The posterior skin dose is of concern due to undesirable bolusing from mounting surfaces the patient lays upon, namely the carbon fiber couch (CFC). The posterior skin dose may be mitigated by positioning the patient on top of a low-density material that separates the patient from the CFC. Purpose: Our objective was to determine the reduction in the posterior surface dose when a mattress or foam board is used to prop the patient away from the CFC. Materials and Methods: Three clinical rectal cancer patient VMAT plans were selected. A solid water phantom with optically stimulated luminescence dosimeters (OSLDs) placed at the posterior surface was mounted using three setups: directly on the CFC, with a mattress on the CFC, and with a 10 cm thick foam board on the CFC. The three VMAT plans were delivered to this phantom, with OSLDs measuring the posterior surface dose with each setup. In the treatment planning system (TPS), the CFC only, mattress, and foam board setups were simulated on the patient’s anatomy with posterior surface doses reported. Results: The OSLD measurements in the phantom showed that the mattress reduced the posterior surface dose on average by 1.3%, and the foam board reduced the dose by 8.3%. The TPS estimates demonstrated that, on average, the mattress reduced the surface dose by 15.8%, and the foam board reduced the dose by 33.0%. It is likely that the TPS had limitations accurately modeling the surface dose, so OSLD measurements were closer to clinical reality. Conclusions: The mattress does not reduce the posterior skin dose enough to warrant its use as a skin sparing device. The CFC produces a bolusing effect that can be reduced by separating the patient from the CFC with a 10 cm thick foam board.

RadiationVol. 6(1)
Sunnybrook Health Science Centre (CA), University of Toronto (CA)
Openalex Percentile: Top 69%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.