A Novel Differential Pathlength Factor Model for Near-Infrared Diffuse Optical Imaging

Near infrared diffuse optical imaging can be performed in reflectance and transmission mode and relies on physical models along with measurements to extract information on changes in chromophore concentration. Continuous-wave near-infrared diffuse optical imaging relies on accurate differential pathlength factors (DPFs) for quantitative chromophore estimation. Existing DPF definitions inherit formulation-dependent limitations that can introduce large errors in modified Beer--Lambert law analyses. These errors are significantly higher at smaller source-detector separations in a reflectance mode of measurement. This minimizes their applicability in situations where large area detection is used and also when signal depth is varying. Using Monte Carlo simulations, we derive two distance- and property-dependent DPF models one ideal and one experimentally practical and benchmark them against standard formulations. The proposed models achieve errors below 10 percent across broad optical conditions, whereas conventional DPFs can exceed 100 percent error. The theoretical predictions are further validated using controlled phantom experiments, demonstrating improved quantitative accuracy in CW-NIR imaging.

Authors

Publication Details

Journal
Biomedical Optics Express
Published
2026-08-18
DOI
https://doi.org/10.1364/boe.601705
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

A Novel Differential Pathlength Factor Model for Near-Infrared Diffuse Optical Imaging

Mini Das, Mannu Bardhan Paul, Kaiser Niknam
Biomedical Optics Express
Optical Imaging and Spectroscopy Techniques
article

A Novel Differential Pathlength Factor Model for Near-Infrared Diffuse Optical Imaging

Mini Das, Mannu Bardhan Paul, Kaiser Niknam
article en

Abstract

Near infrared diffuse optical imaging can be performed in reflectance and transmission mode and relies on physical models along with measurements to extract information on changes in chromophore concentration. Continuous-wave near-infrared diffuse optical imaging relies on accurate differential pathlength factors (DPFs) for quantitative chromophore estimation. Existing DPF definitions inherit formulation-dependent limitations that can introduce large errors in modified Beer--Lambert law analyses. These errors are significantly higher at smaller source-detector separations in a reflectance mode of measurement. This minimizes their applicability in situations where large area detection is used and also when signal depth is varying. Using Monte Carlo simulations, we derive two distance- and property-dependent DPF models one ideal and one experimentally practical and benchmark them against standard formulations. The proposed models achieve errors below 10 percent across broad optical conditions, whereas conventional DPFs can exceed 100 percent error. The theoretical predictions are further validated using controlled phantom experiments, demonstrating improved quantitative accuracy in CW-NIR imaging.

Biomedical Optics Express
Peace, Justice and strong institutions
Openalex Percentile: Top 91%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Novel Differential Pathlength Factor Model for Near-Infrared Diffuse Optical Imaging — Mini Das, Mannu Bardhan Paul, et al. · Biomedical Optics Express (2026) | TGRS Research Map | TGRS