Infusion Rate Standardization: A Data-Driven Approach to Developing Institutional Standards

At a large NCI-designated Cancer Center, standard infusion rates for the administration of cryopreserved Immune Effector Cells (IEC) do not exist in policy. Current practice is to start slowly and increase the rate per patient tolerance. Limited literature is available on rate and administration methods for cryopreserved IECs. While some FDA package inserts define administration methods and infusion rates, most defer to institutional standards. The lack of a national standard has resulted in cancer institutions across the U.S. adopting varying methods. The objective of this retrospective analysis was to propose a standard institutional rate. The nurse educator performed a gap analysis involving a comprehensive literature review, benchmarking with comparable centers, and retrospective data collection. The literature review used search terms: cryopreserved cells, Dimethyl sulfoxide (DMSO), infusion rate, and adverse events. Clinical nurse specialists, pharmacists, and nurse educators from five comparable cancer centers participated in interviews to benchmark administration practices. To assess current institutional practice, the nurse educator collected data on 121 patients who received cryopreserved IECs over the past year at their center. Variables included method of administration, product type, FDA approval status, DMSO concentration, volume infused, infusion time, adverse reactions (AE), and interventions. All AEs were graded using CTCAE criteria. Due to variability in infusion across patients and products, rates were calculated for each administration using volume and completion time to determine mean rates. Benchmarking confirmed the inconsistency of IEC administration methods and rates. While some institutions use fixed rates (e.g., 10 ml/min), others use total time (e.g., infuse over 10 minutes). Administration methods included gravity, syringe push, mechanical pump, and filter use. Although the literature review did not offer guidance on IEC administration, experts have provided robust guidance on hematopoietic stem cells (HSC), which some institutions consider a comparable product. DMSO was a significant AE contributor, with higher volumes and concentrations of DMSO associated with increased AE frequency. Data collected by the nurse educator showed an average gravity infusion rate of 5.89 ml/min and syringe push, 2.23 ml/min. Slowing infusion rates resolved DMSO side effects without pharmacological intervention, with one grade 4 AE requiring infusion termination. Following this analysis, the nurse educator's institution is evaluating the use of fixed infusion rates and mechanical pumps for IEC and HPC products. The findings highlight an opportunity for institutional collaboration to align best practice guidelines. Standardizing administration practices can improve patient outcomes and support the advancement of IEC therapies in oncology.

Authors

Institutions

Publication Details

Journal
Transplantation and Cellular Therapy
Published
2026-02-01
DOI
https://doi.org/10.1016/j.jtct.2025.12.730
Primary Topic
Hematopoietic Stem Cell Transplantation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Infusion Rate Standardization: A Data-Driven Approach to Developing Institutional Standards

Jenae Franklin, Phuong T. Huynh
Transplantation and Cellular Therapy
Hematopoietic Stem Cell Transplantation
article

Infusion Rate Standardization: A Data-Driven Approach to Developing Institutional Standards

Jenae Franklin, Phuong T. Huynh
article en

Abstract

At a large NCI-designated Cancer Center, standard infusion rates for the administration of cryopreserved Immune Effector Cells (IEC) do not exist in policy. Current practice is to start slowly and increase the rate per patient tolerance. Limited literature is available on rate and administration methods for cryopreserved IECs. While some FDA package inserts define administration methods and infusion rates, most defer to institutional standards. The lack of a national standard has resulted in cancer institutions across the U.S. adopting varying methods. The objective of this retrospective analysis was to propose a standard institutional rate. The nurse educator performed a gap analysis involving a comprehensive literature review, benchmarking with comparable centers, and retrospective data collection. The literature review used search terms: cryopreserved cells, Dimethyl sulfoxide (DMSO), infusion rate, and adverse events. Clinical nurse specialists, pharmacists, and nurse educators from five comparable cancer centers participated in interviews to benchmark administration practices. To assess current institutional practice, the nurse educator collected data on 121 patients who received cryopreserved IECs over the past year at their center. Variables included method of administration, product type, FDA approval status, DMSO concentration, volume infused, infusion time, adverse reactions (AE), and interventions. All AEs were graded using CTCAE criteria. Due to variability in infusion across patients and products, rates were calculated for each administration using volume and completion time to determine mean rates. Benchmarking confirmed the inconsistency of IEC administration methods and rates. While some institutions use fixed rates (e.g., 10 ml/min), others use total time (e.g., infuse over 10 minutes). Administration methods included gravity, syringe push, mechanical pump, and filter use. Although the literature review did not offer guidance on IEC administration, experts have provided robust guidance on hematopoietic stem cells (HSC), which some institutions consider a comparable product. DMSO was a significant AE contributor, with higher volumes and concentrations of DMSO associated with increased AE frequency. Data collected by the nurse educator showed an average gravity infusion rate of 5.89 ml/min and syringe push, 2.23 ml/min. Slowing infusion rates resolved DMSO side effects without pharmacological intervention, with one grade 4 AE requiring infusion termination. Following this analysis, the nurse educator's institution is evaluating the use of fixed infusion rates and mechanical pumps for IEC and HPC products. The findings highlight an opportunity for institutional collaboration to align best practice guidelines. Standardizing administration practices can improve patient outcomes and support the advancement of IEC therapies in oncology.

Transplantation and Cellular TherapyVol. 32(2)
Cape Town HVTN Immunology Laboratory / Hutchinson Centre Research Institute of South Africa (ZA), Fred Hutch Cancer Center (US)
Partnerships for the goals
Openalex Percentile: Top 71%
Hematopoietic Stem Cell Transplantation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.