A closed‐loop system for the semi‐continuous measurement of biogenic volatile organic compounds from marine organisms

Abstract The marine environment constitutes a significant source of Biogenic Volatile Organic Compounds (BVOCs) to the atmosphere with impacts on ecosystem functioning, atmospheric particle formation, carbon cycling and climate. However, processes governing BVOC emissions remain largely unconstrained due to their large spatial and temporal variability. Here, we describe a closed‐loop measurement system that couples a Proton Transfer Reaction Time‐of‐Flight Mass Spectrometer (PTR‐ToF‐MS) to gas‐tight chambers which allows for the real‐time semi‐continuous detection of BVOCs emitted by marine organisms under different experimental treatments. We tested our system for adsorptive losses, reproducibility, linearity and accuracy with four BVOCs (dimethyl sulfide (DMS), methanethiol (MeSH), isoprene and α ‐pinene) at concentrations relevant in the marine environment. While all compounds demonstrated linearity ( R 2 ≥ 0.970) between the dissolved and gas phase, the regressions were statistically significant for DMS and MeSH. A direct relationship between compound recovery and compound solubility was observed, with the low solubility compounds isoprene and α ‐pinene demonstrating poor recovery and the higher solubility compounds DMS and MeSH exhibiting greater recovery. The closed‐loop system demonstrated minor compound loss (< 7%) throughout and high reproducibility (> 88.5%). A sampling time of 605 s was determined to be sufficient for signal stabilization of the four target BVOCs during headspace sampling/measurements. The development of this system provides a novel approach for assessing key drivers of BVOC emissions with broad applicability to both marine and freshwater systems.

Authors

Institutions

Publication Details

Journal
Limnology and Oceanography Methods
Published
2026-02-03
DOI
https://doi.org/10.1002/lom3.70028
Primary Topic
Atmospheric chemistry and aerosols
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A closed‐loop system for the semi‐continuous measurement of biogenic volatile organic compounds from marine organisms

Daniel Patrick Harrison, Erin Dunne, Jasmine B. Haskell, Hilton B. Swan et al.
Limnology and Oceanography Methods
Atmospheric chemistry and aerosols
article

A closed‐loop system for the semi‐continuous measurement of biogenic volatile organic compounds from marine organisms

Daniel Patrick Harrison, Erin Dunne, Jasmine B. Haskell, Hilton B. Swan, Bradley D. Eyre, Elisabeth S. M. Deschaseaux
article en

Abstract

Abstract The marine environment constitutes a significant source of Biogenic Volatile Organic Compounds (BVOCs) to the atmosphere with impacts on ecosystem functioning, atmospheric particle formation, carbon cycling and climate. However, processes governing BVOC emissions remain largely unconstrained due to their large spatial and temporal variability. Here, we describe a closed‐loop measurement system that couples a Proton Transfer Reaction Time‐of‐Flight Mass Spectrometer (PTR‐ToF‐MS) to gas‐tight chambers which allows for the real‐time semi‐continuous detection of BVOCs emitted by marine organisms under different experimental treatments. We tested our system for adsorptive losses, reproducibility, linearity and accuracy with four BVOCs (dimethyl sulfide (DMS), methanethiol (MeSH), isoprene and α ‐pinene) at concentrations relevant in the marine environment. While all compounds demonstrated linearity ( R 2 ≥ 0.970) between the dissolved and gas phase, the regressions were statistically significant for DMS and MeSH. A direct relationship between compound recovery and compound solubility was observed, with the low solubility compounds isoprene and α ‐pinene demonstrating poor recovery and the higher solubility compounds DMS and MeSH exhibiting greater recovery. The closed‐loop system demonstrated minor compound loss (< 7%) throughout and high reproducibility (> 88.5%). A sampling time of 605 s was determined to be sufficient for signal stabilization of the four target BVOCs during headspace sampling/measurements. The development of this system provides a novel approach for assessing key drivers of BVOC emissions with broad applicability to both marine and freshwater systems.

Limnology and Oceanography Methods
CSIRO Oceans and Atmosphere (AU), Institut Català de Ciències del Clima (ES), Institut de Ciències del Mar (ES), Southern Cross University (AU)
Life below water
Openalex Percentile: Top 77%
Atmospheric chemistry and aerosols
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.