Application safety of airway devices by German paramedics

Introduction: There is debate about which airway devices are best used by German paramedics – particularly extraglottic airway devices (EGA) – but the perceived application safety of the user has not been considered. Method: In July and August 2023, an online questionnaire developed by the authors was distributed among German paramedics and results were analysed descriptively. Differences between supplementary-trained (ST) and fully trained (FT) paramedics were determined using the Welch test. Factors for developing application safety when using laryngeal tubes (LT) and laryngeal masks (LMA) were analysed using logistic regression. Results: 780 data records were included. Participants have 13.6 years of professional experience (SD 9.1) and 33.0% have completed full-time training. Oropharyngeal tubes and nasopharyngeal tubes were used most frequently in the last 12 months. ST performed significantly better than FT in terms of self-perceived application safety of the use of LT, conventional (cETI) and video-assisted endotracheal intubation (vETI), puncture cricothyrotomy (PC), and overall self-perceived safety. In the logistic regression, years of professional experience ( p =0.003; OR 0.95), ST ( p <0.001; OR 3.68) and use of the simulator ( p =0.048; OR 1.024) had a significant effect on the safety of LT use. Use on the simulator ( p <0.001; OR 1.05) and real patient ( p <0.001; OR 1.08) had significant effects on the self-perceived application safety of the LMA. Conclusion: Results show a differentiated picture of self-perceived application safety, particularly EGA. ST paramedics feel more confident using airway devices than FT colleagues.

Authors

Institutions

Publication Details

Journal
Journal of Paramedic Practice
Published
2026-02-02
DOI
https://doi.org/10.12968/jpar.2025.0054
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application safety of airway devices by German paramedics

Thomas Hofmann, Hanna Grönheim, Annette Kerckhoff, Luis Dipl.-Biol. Möckel et al.
Journal of Paramedic Practice
Airway Management and Intubation Techniques
article

Application safety of airway devices by German paramedics

Thomas Hofmann, Hanna Grönheim, Annette Kerckhoff, Luis Dipl.-Biol. Möckel, Andreas Behrnd
article en

Abstract

Introduction: There is debate about which airway devices are best used by German paramedics – particularly extraglottic airway devices (EGA) – but the perceived application safety of the user has not been considered. Method: In July and August 2023, an online questionnaire developed by the authors was distributed among German paramedics and results were analysed descriptively. Differences between supplementary-trained (ST) and fully trained (FT) paramedics were determined using the Welch test. Factors for developing application safety when using laryngeal tubes (LT) and laryngeal masks (LMA) were analysed using logistic regression. Results: 780 data records were included. Participants have 13.6 years of professional experience (SD 9.1) and 33.0% have completed full-time training. Oropharyngeal tubes and nasopharyngeal tubes were used most frequently in the last 12 months. ST performed significantly better than FT in terms of self-perceived application safety of the use of LT, conventional (cETI) and video-assisted endotracheal intubation (vETI), puncture cricothyrotomy (PC), and overall self-perceived safety. In the logistic regression, years of professional experience ( p =0.003; OR 0.95), ST ( p <0.001; OR 3.68) and use of the simulator ( p =0.048; OR 1.024) had a significant effect on the safety of LT use. Use on the simulator ( p <0.001; OR 1.05) and real patient ( p <0.001; OR 1.08) had significant effects on the self-perceived application safety of the LMA. Conclusion: Results show a differentiated picture of self-perceived application safety, particularly EGA. ST paramedics feel more confident using airway devices than FT colleagues.

Journal of Paramedic PracticeVol. 18(2)
German Society of Surgery (DE), German Society of Sport Science (DE), HSD Hochschule Döpfer (DE), Hochschule für Gesundheit & Sport, Technik & Kunst (DE)
Openalex Percentile: Top 66%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application safety of airway devices by German paramedics — Thomas Hofmann, Hanna Grönheim, et al. · Journal of Paramedic Practice (2026) | TGRS Research Map | TGRS