Experimental study of transformer oil explosion affected by a vertical steel plate

The transformer oil within the piping of ultra-high voltage converter transformers is prone to evaporation, forming a flammable oil–gas mixture. In the presence of an ignition source, an explosion of transformer oil can cause severe damage to the power equipment. Currently, experimental studies on the dynamic evolution of transformer oil explosions are lacking. The effects of transformer oil volume and distance on the overpressure evolution and fireball behavior of transformer oil explosions are investigated, as well as the blast resistance performance of the clamped steel plate. Experimental results show that as the distance between the pressure measurement point and the explosion center increases, the peak overpressure gradually decreases. When the transformer oil volume increases from 8 to 16 l, the fireball behavior induced by the explosive charge remains similar, but the peak overpressure decreases. The explosion of 16 l of transformer oil produces the largest fireball radius and maximum area among all tested oil volumes. Due to the limitations of the explosive charge and oil volume, the peak overpressure reached ∼43.67 kPa, which did not cause noticeable damage to the clamped steel plate.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2026-02-01
DOI
https://doi.org/10.1063/5.0314321
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study of transformer oil explosion affected by a vertical steel plate

Xianli Zhu, Lingxin He, Yubiao Huang, Jiaqing Zhang
AIP Advances
Power Transformer Diagnostics and Insulation
article

Experimental study of transformer oil explosion affected by a vertical steel plate

Xianli Zhu, Lingxin He, Yubiao Huang, Jiaqing Zhang
article en

Abstract

The transformer oil within the piping of ultra-high voltage converter transformers is prone to evaporation, forming a flammable oil–gas mixture. In the presence of an ignition source, an explosion of transformer oil can cause severe damage to the power equipment. Currently, experimental studies on the dynamic evolution of transformer oil explosions are lacking. The effects of transformer oil volume and distance on the overpressure evolution and fireball behavior of transformer oil explosions are investigated, as well as the blast resistance performance of the clamped steel plate. Experimental results show that as the distance between the pressure measurement point and the explosion center increases, the peak overpressure gradually decreases. When the transformer oil volume increases from 8 to 16 l, the fireball behavior induced by the explosive charge remains similar, but the peak overpressure decreases. The explosion of 16 l of transformer oil produces the largest fireball radius and maximum area among all tested oil volumes. Due to the limitations of the explosive charge and oil volume, the peak overpressure reached ∼43.67 kPa, which did not cause noticeable damage to the clamped steel plate.

AIP AdvancesVol. 16(2)
Electric Power Research Institute (US), State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 69%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.