Assessment of thermal comfort in a medium size mosque in hot climates

Purpose Thermal comfort in high-occupancy buildings such as mosques, where many gather for worship, is crucial. This study aims to evaluate the effects of thermal comfort on occupants in hot climates and compare the results with acceptable standards. Design/methodology/approach This study evaluated the thermal comfort of mosque occupants by measuring temperature, humidity and air velocity, and compared the experimental findings to acceptable standards. It included a psychosocial perception survey and analyzed Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) to ascertain the thermal comfort zone. Findings The findings identified key factors impacting indoor thermal comfort for mosque worshippers, including air temperature, humidity and air velocity. The presence of draughts from split air conditioning units, particularly in the corners of the prayer hall, diminished thermal comfort by generating localized cold spots during worship sessions. Using the CBE thermal comfort tool, PMV and PPD values were calculated per ASHRAE and EN-16798 standards. PMV values of −1.27 and −1.12 indicate a “slightly cool” sensation, while corresponding PPD values of 39% and 31% represent the percentage of occupants likely to feel thermally dissatisfied, of which both calculated metrics are significantly off the acceptable standards of 10% (PPD) and −0.5 to +0.5 (PMV). Originality/value This study will considerably advance thermal comfort theory, policy and practice in religious buildings, particularly medium-sized mosques in hot climates, by enabling architectural regulatory agencies to implement design best practices and use data-driven insights for more effective and sustainable building codes.

Authors

Institutions

Publication Details

Journal
Facilities
Published
2025-09-26
DOI
https://doi.org/10.1108/f-02-2025-0026
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of thermal comfort in a medium size mosque in hot climates

Mohammed Alhaji Mohammed, Umar Haruna, Yusuff A. Ajibade
Facilities
Building Energy and Comfort Optimization
article

Assessment of thermal comfort in a medium size mosque in hot climates

Mohammed Alhaji Mohammed, Umar Haruna, Yusuff A. Ajibade
article en

Abstract

Purpose Thermal comfort in high-occupancy buildings such as mosques, where many gather for worship, is crucial. This study aims to evaluate the effects of thermal comfort on occupants in hot climates and compare the results with acceptable standards. Design/methodology/approach This study evaluated the thermal comfort of mosque occupants by measuring temperature, humidity and air velocity, and compared the experimental findings to acceptable standards. It included a psychosocial perception survey and analyzed Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) to ascertain the thermal comfort zone. Findings The findings identified key factors impacting indoor thermal comfort for mosque worshippers, including air temperature, humidity and air velocity. The presence of draughts from split air conditioning units, particularly in the corners of the prayer hall, diminished thermal comfort by generating localized cold spots during worship sessions. Using the CBE thermal comfort tool, PMV and PPD values were calculated per ASHRAE and EN-16798 standards. PMV values of −1.27 and −1.12 indicate a “slightly cool” sensation, while corresponding PPD values of 39% and 31% represent the percentage of occupants likely to feel thermally dissatisfied, of which both calculated metrics are significantly off the acceptable standards of 10% (PPD) and −0.5 to +0.5 (PMV). Originality/value This study will considerably advance thermal comfort theory, policy and practice in religious buildings, particularly medium-sized mosques in hot climates, by enabling architectural regulatory agencies to implement design best practices and use data-driven insights for more effective and sustainable building codes.

FacilitiesVol. 43(13-14)
King Fahd University of Petroleum and Minerals (SA)
Climate action
Openalex Percentile: Top 33%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.