Towards a Traceable Calibration of Medium Voltage Transformers up to 150 kHz

The increasing integration of power electronics and renewable energy sources in modern electrical grids has introduced new challenges in medium voltage transformer calibration, particularly in the frequency range from 9 kHz to 150 kHz. Accurate and traceable calibration methods are essential to ensure reliable voltage measurement in electrical grids, where power quality and compliance with IEC 61869-1:2024 standards are critical. This study presents advancements in the development of traceable calibration techniques for medium voltage transformers operating within this frequency range. The approach includes the design of generators capable of simulating real world grid disturbances and the establishment of reference measurement systems at National Metrology Institutes. The study further explores generator configurations, such as parallel and series source arrangements, to extend calibration capabilities beyond existing limits. The proposed calibration methodology incorporates precision voltage dividers with high resolution, filtering and amplification techniques, and advanced data acquisition methods to achieve measurement uncertainties below 0.01% for fundamental components and between 0.2 % and 1 % for harmonic components. A key challenge is the ability to measure a fundamental voltage as high as 50 kV while superimposing harmonics with amplitudes as low as 5 V in the 9 kHz to 150 kHz range. These developments aim to enhance power system reliability, improve voltage measurement accuracy, and support the transition to more efficient and resilient electrical grids. The presented results lay the foundation for future calibration services.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-07
DOI
https://doi.org/10.1051/epjconf/202532312007/pdf
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards a Traceable Calibration of Medium Voltage Transformers up to 150 kHz

Palma Sara Letizia, Mohamed AGAZAR, Claudio Iodice, Tatu Nieminen et al.
Springer Link (Chiba Institute of Technology)
Advanced Electrical Measurement Techniques
article

Towards a Traceable Calibration of Medium Voltage Transformers up to 150 kHz

Palma Sara Letizia, Mohamed AGAZAR, Claudio Iodice, Tatu Nieminen, Jari Hällström, Jorge Rovira, Domenico Giordano, Angel Ramírez, Mario Luiso, Alf-Peter Elg
article en

Abstract

The increasing integration of power electronics and renewable energy sources in modern electrical grids has introduced new challenges in medium voltage transformer calibration, particularly in the frequency range from 9 kHz to 150 kHz. Accurate and traceable calibration methods are essential to ensure reliable voltage measurement in electrical grids, where power quality and compliance with IEC 61869-1:2024 standards are critical. This study presents advancements in the development of traceable calibration techniques for medium voltage transformers operating within this frequency range. The approach includes the design of generators capable of simulating real world grid disturbances and the establishment of reference measurement systems at National Metrology Institutes. The study further explores generator configurations, such as parallel and series source arrangements, to extend calibration capabilities beyond existing limits. The proposed calibration methodology incorporates precision voltage dividers with high resolution, filtering and amplification techniques, and advanced data acquisition methods to achieve measurement uncertainties below 0.01% for fundamental components and between 0.2 % and 1 % for harmonic components. A key challenge is the ability to measure a fundamental voltage as high as 50 kV while superimposing harmonics with amplitudes as low as 5 V in the 9 kHz to 150 kHz range. These developments aim to enhance power system reliability, improve voltage measurement accuracy, and support the transition to more efficient and resilient electrical grids. The presented results lay the foundation for future calibration services.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 37%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards a Traceable Calibration of Medium Voltage Transformers up to 150 kHz — Palma Sara Letizia, Mohamed AGAZAR, et al. · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS