A Benchtop Evaluation of Cervical Collar Design and Strap Tension

Abstract: This article presents a novel experimental setup for objectively evaluating cervical collar design and fit by monitoring strap tension and interface pressures across the device-skin interface. This study evaluated four commercially available cervical collars, achieving repeatable findings (ICC > 0.93) that were sensitive to differences between collars and across strap tensions. For each collar, there was a significant relationship (r > 0.4, p < 0.005) between strap tension and interface pressure values, with pressures exceeding 100 mmHg for high strap tensions. Differences in the distribution of pressures and the relationship between strap tension and interface pressures highlight the need for these objective measures of design and fit for cervical collars to evaluate new and existing designs. Keywords: cervical collars, pressure ulcers, interface pressure

Authors

Institutions

Publication Details

Journal
Medical Devices Evidence and Research
Published
2026-02-01
DOI
https://doi.org/10.2147/mder.s541594
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Benchtop Evaluation of Cervical Collar Design and Strap Tension

Davide Filingeri, Laurence Russell, Liudi Jiang, Peter Worsley
Medical Devices Evidence and Research
Cervical and Thoracic Myelopathy
article

A Benchtop Evaluation of Cervical Collar Design and Strap Tension

Davide Filingeri, Laurence Russell, Liudi Jiang, Peter Worsley
article en

Abstract

Abstract: This article presents a novel experimental setup for objectively evaluating cervical collar design and fit by monitoring strap tension and interface pressures across the device-skin interface. This study evaluated four commercially available cervical collars, achieving repeatable findings (ICC > 0.93) that were sensitive to differences between collars and across strap tensions. For each collar, there was a significant relationship (r > 0.4, p < 0.005) between strap tension and interface pressure values, with pressures exceeding 100 mmHg for high strap tensions. Differences in the distribution of pressures and the relationship between strap tension and interface pressures highlight the need for these objective measures of design and fit for cervical collars to evaluate new and existing designs. Keywords: cervical collars, pressure ulcers, interface pressure

Medical Devices Evidence and ResearchVol. Volume 19
University of Southampton (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 69%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.