MR Optimum: A web-based open-source tool for standardized signal-to-noise ratio evaluation in MRI

• First comprehensive open-source web tool for SNR evaluation in MRI • Supports multiple SNR estimation methods and image reconstruction algorithms- • Modular cloud-native architecture for accessible, reproducible, scalable SNR assessment • Interactive GUI allows visualization and analysis of SNR, g factor, and coil sensitivity maps • Results are exportable in NIfTI, MATLAB, and JSON format for downstream integration and QA Signal-to-noise ratio (SNR) is a key performance metric in magnetic resonance imaging (MRI) to evaluate pulse sequences, receive coils, and image reconstruction algorithms. A variety of methods have been proposed to estimate SNR. However, the lack of consistent and broadly available open-source implementations has been a challenge for reliable SNR comparisons in clinical and research settings. To address this gap, this work introduces MR Optimum, a cloud-native, open-source platform for standardized SNR analysis. MR Optimum integrates established SNR estimation techniques within a flexible, modular software architecture. A web-based user interface supports data upload, task configuration, cloud computations, and real-time results visualization. MR Optimum leverages serverless computing technologies (AWS Lambda and Fargate) to perform scalable, event-driven processing of MRI rawdata and allow users to calculate SNR using established methods: multiple replicas, pseudo multiple replicas, generalized pseudo multiple replicas, and analytic methods. Results include SNR maps, noise covariance and noise coefficient matrices, coil sensitivity profiles, and g factor maps. The web interface enables interactive visualization and histogram analysis based on regions of interest. Results can be exported in MATLAB, NIfTI, and JSON formats. By providing a unified computational environment, MR Optimum ensures reproducibility, and democratizes access to state-of-the-art SNR estimation, promoting multi-center harmonization and quality assurance.

Authors

Institutions

Publication Details

Journal
Computer Methods and Programs in Biomedicine Update
Published
2026-02-02
DOI
https://doi.org/10.1016/j.cmpbup.2026.100235
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MR Optimum: A web-based open-source tool for standardized signal-to-noise ratio evaluation in MRI

Eros Montin, Riccardo Lattanzi, Xuan Thao Nguyen
Computer Methods and Programs in Biomedicine Update
Advanced MRI Techniques and Applications
article

MR Optimum: A web-based open-source tool for standardized signal-to-noise ratio evaluation in MRI

Eros Montin, Riccardo Lattanzi, Xuan Thao Nguyen
article en

Abstract

• First comprehensive open-source web tool for SNR evaluation in MRI • Supports multiple SNR estimation methods and image reconstruction algorithms- • Modular cloud-native architecture for accessible, reproducible, scalable SNR assessment • Interactive GUI allows visualization and analysis of SNR, g factor, and coil sensitivity maps • Results are exportable in NIfTI, MATLAB, and JSON format for downstream integration and QA Signal-to-noise ratio (SNR) is a key performance metric in magnetic resonance imaging (MRI) to evaluate pulse sequences, receive coils, and image reconstruction algorithms. A variety of methods have been proposed to estimate SNR. However, the lack of consistent and broadly available open-source implementations has been a challenge for reliable SNR comparisons in clinical and research settings. To address this gap, this work introduces MR Optimum, a cloud-native, open-source platform for standardized SNR analysis. MR Optimum integrates established SNR estimation techniques within a flexible, modular software architecture. A web-based user interface supports data upload, task configuration, cloud computations, and real-time results visualization. MR Optimum leverages serverless computing technologies (AWS Lambda and Fargate) to perform scalable, event-driven processing of MRI rawdata and allow users to calculate SNR using established methods: multiple replicas, pseudo multiple replicas, generalized pseudo multiple replicas, and analytic methods. Results include SNR maps, noise covariance and noise coefficient matrices, coil sensitivity profiles, and g factor maps. The web interface enables interactive visualization and histogram analysis based on regions of interest. Results can be exported in MATLAB, NIfTI, and JSON formats. By providing a unified computational environment, MR Optimum ensures reproducibility, and democratizes access to state-of-the-art SNR estimation, promoting multi-center harmonization and quality assurance.

Computer Methods and Programs in Biomedicine UpdateVol. 9
New York University (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 70%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MR Optimum: A web-based open-source tool for standardized signal-to-noise ratio evaluation in MRI — Eros Montin, Riccardo Lattanzi, et al. · Computer Methods and Programs in Biomedicine Update (2026) | TGRS Research Map | TGRS