Enhancement of Reference Power Standard at SASO NMCC on AC power And revaluation of measurement uncertainty

The accuracy and reliability of Power Standards for AC power measurements are significant subjects in current times and for the future. The rapid increase in smart electricity meters in Saudi Arabia necessitates the development of an NMCC (National Metrology and Calibration Center) reference power standard to meet legal metrology and industrial requirements. This study explores advancements in reference power standards, specifically focusing on the development of more precise and stable AC power measurement systems for high-current applications. The results demonstrate a significant reduction in the estimated uncertainty, leading to more accurate calibration of power meters. In a parallel case study, a calibration method is applied to a commercial power meter to measure AC power across high current values ranging from 10 A to 120 A using Refernce CT. The calibration method involves comparing the reference AC power system with the commercial power meter. The term ‘DSWM’ (Digital Sampling Watt Meter) refers to the reference AC power system, which utilizes sampling techniques to collect various data with a Unit under Calibration (UUC). Homemade software under the environment of LabVIEW software is used to controlling, optimizing, handling the data, statistically calculation and finally for exporting the well gathering data in the form in digitized certificates. The paper explains the components of the DSWM, the measurement results for AC power are presented, considering active and reactive power, which may impact various aspects such as voltage, current, and phase measurements. The evaluation of uncertainty was 40 μW/V.A for active power and 40 μvar/V.A for reactive power. Finally, the paper mentions future work in its concluding section.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-07
DOI
https://doi.org/10.1051/epjconf/202532312004/pdf
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancement of Reference Power Standard at SASO NMCC on AC power And revaluation of measurement uncertainty

R. A. Alrumie, Saleh Almojaewel, Saad Bin Qoud
Springer Link (Chiba Institute of Technology)
Advanced Electrical Measurement Techniques
article

Enhancement of Reference Power Standard at SASO NMCC on AC power And revaluation of measurement uncertainty

R. A. Alrumie, Saleh Almojaewel, Saad Bin Qoud
article en

Abstract

The accuracy and reliability of Power Standards for AC power measurements are significant subjects in current times and for the future. The rapid increase in smart electricity meters in Saudi Arabia necessitates the development of an NMCC (National Metrology and Calibration Center) reference power standard to meet legal metrology and industrial requirements. This study explores advancements in reference power standards, specifically focusing on the development of more precise and stable AC power measurement systems for high-current applications. The results demonstrate a significant reduction in the estimated uncertainty, leading to more accurate calibration of power meters. In a parallel case study, a calibration method is applied to a commercial power meter to measure AC power across high current values ranging from 10 A to 120 A using Refernce CT. The calibration method involves comparing the reference AC power system with the commercial power meter. The term ‘DSWM’ (Digital Sampling Watt Meter) refers to the reference AC power system, which utilizes sampling techniques to collect various data with a Unit under Calibration (UUC). Homemade software under the environment of LabVIEW software is used to controlling, optimizing, handling the data, statistically calculation and finally for exporting the well gathering data in the form in digitized certificates. The paper explains the components of the DSWM, the measurement results for AC power are presented, considering active and reactive power, which may impact various aspects such as voltage, current, and phase measurements. The evaluation of uncertainty was 40 μW/V.A for active power and 40 μvar/V.A for reactive power. Finally, the paper mentions future work in its concluding section.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 37%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.