New Structure for High-Sensitivity Coaxial Thermal Power Sensor in the Frequency Range from DC–50 GHz

This paper presents the design and development of a new thermal microwave power sensor for a frequency range spanning from DC to 50 GHz. The purpose of this new design is to propose a high-sensitivity thermoelectric power sensor suitable for microcalorimeter application that is a primary method of microwave power calibration. The core structure of the power sensor comprises a Grounded Coplanar Waveguide (GCPW) transmission line, two load resistors, a thermopile, and output pads for DC measurements. The optimized power sensor demonstrates promising simulation performance, with a return loss better than 20 dB across the frequency range and an efficiency exceeding 80%. At 50 GHz, the sensitivity of the power sensor reaches well over 0.240 mV/mW.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-07
DOI
https://doi.org/10.1051/epjconf/202532312005/pdf
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Structure for High-Sensitivity Coaxial Thermal Power Sensor in the Frequency Range from DC–50 GHz

Jean-Marie Lerat, Doudou Ba
Springer Link (Chiba Institute of Technology)
Microwave and Dielectric Measurement Techniques
article

New Structure for High-Sensitivity Coaxial Thermal Power Sensor in the Frequency Range from DC–50 GHz

Jean-Marie Lerat, Doudou Ba
article en

Abstract

This paper presents the design and development of a new thermal microwave power sensor for a frequency range spanning from DC to 50 GHz. The purpose of this new design is to propose a high-sensitivity thermoelectric power sensor suitable for microcalorimeter application that is a primary method of microwave power calibration. The core structure of the power sensor comprises a Grounded Coplanar Waveguide (GCPW) transmission line, two load resistors, a thermopile, and output pads for DC measurements. The optimized power sensor demonstrates promising simulation performance, with a return loss better than 20 dB across the frequency range and an efficiency exceeding 80%. At 50 GHz, the sensitivity of the power sensor reaches well over 0.240 mV/mW.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 37%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.