Invited - High-resolution, Data-driven 3D X-ray Imaging of Microchips using Ptychography
As transistor dimensions have shrunk over the years, X-ray microscopy resolution has also improved to meet the demands of the semiconductor industry. Although electron microscopy can achieve higher resolution, X-rays offer unique advantages, including non-destructive 3D imaging of fully intact integrated circuit dies and the future possibility of imaging under operando conditions. In this work, we demonstrate the capabilities of ptychographic X-ray computed tomography for 3D microchip imaging at 4 nm resolution. To achieve such performance, we introduce newly developed methods to overcome nm-scale experimental instabilities and depth-of-field limitations. Microchip-specific high-throughput data collection methods will also be introduced.
Authors
- Ana Díaz (ORCID: https://orcid.org/0000-0003-0479-4752)
- Tomas Aidukas
- Nicholas Phillips (ORCID: https://orcid.org/0000-0002-9742-7937)
- Emiliya Poghosyan (ORCID: https://orcid.org/0000-0002-0961-731X)
- A. F. J. Levi (ORCID: https://orcid.org/0000-0002-6983-2855)
- Manuel Guizar-Sicairos
- Gabriel Aeppli
- Elisabeth Müller
- Mirko Holler
Publication Details
- Journal
- Springer Link (Chiba Institute of Technology)
- Published
- 2025-09-22
- DOI
- https://doi.org/10.1051/epjconf/202533501001/pdf
- Primary Topic
- Advanced X-ray Imaging Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00