Fungus assessment in indoor environment of old buildings in Peninsular Malaysia

Older buildings often face challenges related to physical deterioration and material decay, which can lead to fungal contamination and the development of sick building syndrome (SBS). In Malaysia, there have been limited studies on the occurrence of fungal identification in indoor air, particularly in old buildings. This study focused on determining the fungal diversity and total fungal load (expressed in colony-forming units, CFU/m3) in selected old buildings in Peninsular Malaysia. Samples were collected from indoor air, building materials (painted walls and ceilings) and swabs at 18 sites within two selected old buildings (A and B) known to have fungal issues. A total of 182 indoor air, 76 scraped and 75 swabbed samples were collected from June to November 2021. Molecular identification was performed by extracting DNA from fungal isolates and amplifying the internal transcribed spacer (ITS) region using polymerase chain reaction (PCR). The fungal load, measured as ranging from 215 to 5235 CFU/m3, with five sites exceeding the Industry Code of Practice on Indoor Air Quality (ICOP IAQ) guidelines: two in building A and three in building B. Higher loads of fungi were identified in the indoor air samples. The most frequently identified genera in both buildings were Aspergillus spp., Penicillium spp. and Cladosporium spp. Dominant species were A. niger, P. citrinum, A. tamarii, C. haloterans and C. cladosporoides. These findings demonstrate the considerable diversity and extent of fungal contamination present in older buildings, underscoring the potential health risks associated with exposure to indoor fungi.

Authors

Institutions

Publication Details

Journal
Aerobiologia
Published
2026-02-03
DOI
https://doi.org/10.1007/s10453-026-09903-2
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fungus assessment in indoor environment of old buildings in Peninsular Malaysia

Ratna Mohd Tap, Masratul Hawa Mohd, Nur Amalina Kamarudin, Nurul Izzah Ahmad et al.
Aerobiologia
Indoor Air Quality and Microbial Exposure
article

Fungus assessment in indoor environment of old buildings in Peninsular Malaysia

Ratna Mohd Tap, Masratul Hawa Mohd, Nur Amalina Kamarudin, Nurul Izzah Ahmad, Cathrinena Robun, Anis Syuhada Omar Hamdan, Mohd Fairulnizal Md Noh, Yin-Hui Leong
article en

Abstract

Older buildings often face challenges related to physical deterioration and material decay, which can lead to fungal contamination and the development of sick building syndrome (SBS). In Malaysia, there have been limited studies on the occurrence of fungal identification in indoor air, particularly in old buildings. This study focused on determining the fungal diversity and total fungal load (expressed in colony-forming units, CFU/m3) in selected old buildings in Peninsular Malaysia. Samples were collected from indoor air, building materials (painted walls and ceilings) and swabs at 18 sites within two selected old buildings (A and B) known to have fungal issues. A total of 182 indoor air, 76 scraped and 75 swabbed samples were collected from June to November 2021. Molecular identification was performed by extracting DNA from fungal isolates and amplifying the internal transcribed spacer (ITS) region using polymerase chain reaction (PCR). The fungal load, measured as ranging from 215 to 5235 CFU/m3, with five sites exceeding the Industry Code of Practice on Indoor Air Quality (ICOP IAQ) guidelines: two in building A and three in building B. Higher loads of fungi were identified in the indoor air samples. The most frequently identified genera in both buildings were Aspergillus spp., Penicillium spp. and Cladosporium spp. Dominant species were A. niger, P. citrinum, A. tamarii, C. haloterans and C. cladosporoides. These findings demonstrate the considerable diversity and extent of fungal contamination present in older buildings, underscoring the potential health risks associated with exposure to indoor fungi.

AerobiologiaVol. 42(1)
Universiti Sains Malaysia (MY), Universiti Teknologi MARA System (MY)
Universiti Sains Malaysia
Sustainable cities and communities
Openalex Percentile: Top 71%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.