Supramolecular fluorescent chemosensor with logic gate operations for Pb2+ detection in field-collected water samples
Lead (Pb 2+ ) contamination poses a serious threat to human health and aquatic ecosystems, demanding rapid, sensitive, and reliable detection strategies. Herein, we report a novel, low-cost, and robust Tetramethoxyresorcin[4]arene-based supramolecular fluorescent chemosensor series TMT-PBAP(2a–2d) for selective Pb 2+ recognition. Unlike previously reported sensors, TMT-PBAP achieves ultra-sensitive nanomolar detection 1.16 nM, demonstrating exceptional analytical performance. Structural conversion from TMT-NAP(1a-1d) to TMT-PBAP(2a-2d) produced an optimized binding cavity, enabling strong host–guest supported with ICT and CHEF mechanism. The sensors exhibit high binding constants K = 6.04 × 10 7 M −1 with fluorescence recovery rates of 95–99% with R 2 = 0.99, and real-sample validation in tap and river water consistent with ICP-AES measurements, confirming both sensitivity and practical reliability. Detailed studies, including UV–Vis, fluorescence titration, stoichiometry, anti-interference, pH stability, photobleachability, and DFT calculations , confirmed the selective Pb 2+ binding mechanism. Moreover, the reversible fluorescence enabled molecular logic gate construction, highlighting multifunctional capability. Overall, this work presents a novel, cost-effective, and high-performance supramolecular platform for trace Pb 2+ detection, with strong potential for portable, real-time environmental monitoring in complex environments, providing a sustainable solution for water quality management and environmental safety. Schematic illustration of the fluorescence turn-on sensing mechanism of the TMT-PBAP chemosensor before and after Pb²⁺ ion binding • Tetramethoxyresorcin[4]arene-based supramolecular chemosensor for selective turn-on fluorescence detection of Pb 2+ . • Achieves detection limits below WHO drinking water standards. • Demonstrates strong stability and reproducibility under varied environmental conditions. • Exhibits integrated logic gate functionality for intelligent water quality monitoring and molecular computing.
Authors
- Manoj Vora (ORCID: https://orcid.org/0000-0002-9603-4576)
- Hitesh M. Parekh (ORCID: https://orcid.org/0000-0002-2949-0280)
- Ronak S Patel
- Rachit V. Patel
- Meet K. Panchal
- Zalak G. Thakker
- Disha H. Patel
Institutions
- General Motors (India) (IN)
- Sardar Patel University (IN)
Publication Details
- Journal
- Journal of Water Process Engineering
- Published
- 2026-02-03
- DOI
- https://doi.org/10.1016/j.jwpe.2026.109642
- Citations
- 1
- Primary Topic
- Molecular Sensors and Ion Detection
- Type
- article
- Field-Weighted Citation Impact
- 16.26