Weighted average algorithm adjusted a novel (1 + FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack

The integration of diverse energy sources and the advent of smart grids have intensified the challenges in load frequency management (LFM). Modern power systems are increasingly vulnerable to inherent nonlinearities, such as generation rate constraints, governor dead bands, boiler dynamics, and communication delays, as well as sophisticated cyber-attacks, which collectively threaten frequency stability and tie-line power balance. To address these challenges, this study proposes a novel cascade controller, designated as (1 + FOPI)-FOPI-TID, for robust automatic generation control in hybrid two-area power systems. The controller uniquely combines fractional-order (FO) dynamics with a tilt-integral-derivative stage and is optimized using a green metaheuristic, the weighted average algorithm (WAA). The WAA effectively balances exploration and exploitation to achieve superior parameter tuning. The proposed control architecture processes both area control error (ACE) and frequency deviation (ΔF) signals through dedicated stages, enabling enhanced disturbance rejection and transient response. The system model incorporates a comprehensive set of nonlinearities and evaluates resilience against resonance-based cyber-attacks. Comprehensive simulation studies under both AC and HVDC tie-line configurations demonstrate that the WAA-optimized (1 + FOPI)-FOPI-TID controller significantly outperforms existing schemes, including PD-PI, PIFOD-(1 + PI), and PIDF(1 + FOD). Key performance metrics show a 45.3% reduction in the integral of time-weighted absolute error (ITAE) and improvements in settling times of 47.7% for ΔF₁ and 32.8% for ΔF₂. Sensitivity analysis confirms robustness under ± 25% parameter variations and random load perturbations. During cyber-attacks, the controller maintains the lowest Rate of Change of Frequency (RoCoF), underscoring its dual capability in stabilizing grid dynamics and mitigating cyber-physical threats. These results validate the controller's potential to enhance operational resilience and reliability in future smart grids.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-02
DOI
https://doi.org/10.1038/s41598-026-37004-0
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Weighted average algorithm adjusted a novel (1 + FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack

Jimmy Nabende Wanzala, Johnes Obungoloch, M A Awal, Michael Robson Atim et al.
Scientific Reports
Frequency Control in Power Systems
article

Weighted average algorithm adjusted a novel (1 + FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack

Jimmy Nabende Wanzala, Johnes Obungoloch, M A Awal, Michael Robson Atim, Mohamed Barakat
article en

Abstract

The integration of diverse energy sources and the advent of smart grids have intensified the challenges in load frequency management (LFM). Modern power systems are increasingly vulnerable to inherent nonlinearities, such as generation rate constraints, governor dead bands, boiler dynamics, and communication delays, as well as sophisticated cyber-attacks, which collectively threaten frequency stability and tie-line power balance. To address these challenges, this study proposes a novel cascade controller, designated as (1 + FOPI)-FOPI-TID, for robust automatic generation control in hybrid two-area power systems. The controller uniquely combines fractional-order (FO) dynamics with a tilt-integral-derivative stage and is optimized using a green metaheuristic, the weighted average algorithm (WAA). The WAA effectively balances exploration and exploitation to achieve superior parameter tuning. The proposed control architecture processes both area control error (ACE) and frequency deviation (ΔF) signals through dedicated stages, enabling enhanced disturbance rejection and transient response. The system model incorporates a comprehensive set of nonlinearities and evaluates resilience against resonance-based cyber-attacks. Comprehensive simulation studies under both AC and HVDC tie-line configurations demonstrate that the WAA-optimized (1 + FOPI)-FOPI-TID controller significantly outperforms existing schemes, including PD-PI, PIFOD-(1 + PI), and PIDF(1 + FOD). Key performance metrics show a 45.3% reduction in the integral of time-weighted absolute error (ITAE) and improvements in settling times of 47.7% for ΔF₁ and 32.8% for ΔF₂. Sensitivity analysis confirms robustness under ± 25% parameter variations and random load perturbations. During cyber-attacks, the controller maintains the lowest Rate of Change of Frequency (RoCoF), underscoring its dual capability in stabilizing grid dynamics and mitigating cyber-physical threats. These results validate the controller's potential to enhance operational resilience and reliability in future smart grids.

Scientific ReportsVol. 16(1)
Mbarara University of Science and Technology (UG), Busitema University (UG), Egyptian Center for Innovation and Technology Development (EG), Research Institute of Ophthalmology (EG)
Affordable and clean energy
Openalex Percentile: Top 69%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.