Simultaneous Dissolved Gas Analysis in Transformer Oil via Time-Division-Multiplexed Quartz-Enhanced Photoacoustic Spectroscopy

Dissolved gas analysis (DGA) is an essential method for monitoring and diagnosing faults in oil-immersed transformers. Acetylene (C<sub>2</sub>H<sub>2</sub>) and methane (CH<sub>4</sub>) are key indicator gases for fault identification. We report for the first time a time-division-multiplexed quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system capable of simultaneously and sensitively detecting dissolved C<sub>2</sub>H<sub>2</sub> and CH<sub>4</sub>, even with an extremely small amount of required sample gas. The on-beam configuration enhanced the 2<i>f</i> signal amplitude by nearly 20-fold. The sensing system achieved minimum detection limits (MDLs) of approximately 15 ppb for C<sub>2</sub>H<sub>2</sub> and 0.3 ppm for CH<sub>4</sub>, which are 2-3 orders of magnitude lower than the safety thresholds defined in the relevant industry standards. The detectability of the sensing system satisfies the requirements for DGA in transformer oil. With a gas cell volume of approximately 1.6 mL, the system markedly reduces the required oil sample volume. By integrating headspace degassing with QEPAS, the sensing system enables real-time monitoring and analysis of the oil-gas equilibrium behavior of dissolved C<sub>2</sub>H<sub>2</sub> and CH<sub>4</sub>. With its high sensitivity, rapid response, and low sample consumption, the proposed sensing system provides a viable and efficient approach for early detection of transformer faults. Furthermore, it establishes a foundation for applying QEPAS to dissolved gas analysis in transformer oil.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-02-02
DOI
https://doi.org/10.1021/acs.analchem.5c07335
Citations
3
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
48.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Dissolved Gas Analysis in Transformer Oil via Time-Division-Multiplexed Quartz-Enhanced Photoacoustic Spectroscopy

Chaofan Feng, Yixin Zhang, Y. H. Chen, Qingyuan Tian et al.
3 citations
Analytical Chemistry
Spectroscopy and Laser Applications
48.78
article

Simultaneous Dissolved Gas Analysis in Transformer Oil via Time-Division-Multiplexed Quartz-Enhanced Photoacoustic Spectroscopy

Chaofan Feng, Yixin Zhang, Y. H. Chen, Qingyuan Tian, Y. Wang, Jialiang Dai, Chenglong Wang, Ruyue Cui, Lei Dong, Xukun Yin, Hongpeng Wu, Jiapeng Wang
article en
3 citations

Abstract

Dissolved gas analysis (DGA) is an essential method for monitoring and diagnosing faults in oil-immersed transformers. Acetylene (C<sub>2</sub>H<sub>2</sub>) and methane (CH<sub>4</sub>) are key indicator gases for fault identification. We report for the first time a time-division-multiplexed quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system capable of simultaneously and sensitively detecting dissolved C<sub>2</sub>H<sub>2</sub> and CH<sub>4</sub>, even with an extremely small amount of required sample gas. The on-beam configuration enhanced the 2<i>f</i> signal amplitude by nearly 20-fold. The sensing system achieved minimum detection limits (MDLs) of approximately 15 ppb for C<sub>2</sub>H<sub>2</sub> and 0.3 ppm for CH<sub>4</sub>, which are 2-3 orders of magnitude lower than the safety thresholds defined in the relevant industry standards. The detectability of the sensing system satisfies the requirements for DGA in transformer oil. With a gas cell volume of approximately 1.6 mL, the system markedly reduces the required oil sample volume. By integrating headspace degassing with QEPAS, the sensing system enables real-time monitoring and analysis of the oil-gas equilibrium behavior of dissolved C<sub>2</sub>H<sub>2</sub> and CH<sub>4</sub>. With its high sensitivity, rapid response, and low sample consumption, the proposed sensing system provides a viable and efficient approach for early detection of transformer faults. Furthermore, it establishes a foundation for applying QEPAS to dissolved gas analysis in transformer oil.

Analytical ChemistryVol. 98(6)
Xidian University (CN), Shanxi University of Traditional Chinese Medicine (CN), Quantum Technologies (Sweden) (SE)
Industry, innovation and infrastructure
Openalex Percentile: Top 0%
Spectroscopy and Laser Applications
48.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.