Tunable Ion-Sensing Using Coulometric-Based Protocols with Permselective Nanomembranes

Herein, we investigate all-solid-state ion-selective electrodes (ISEs) based on permselective nanomembranes (thickness ∼230 nm) in a coulometric mode. The detection of the potassium ion (K<sup>+</sup>) has been selected as proof of concept, implementing two electrochemical protocols based on the anodic and cathodic readouts of the same ISE. The electrode consists of an ITO glass substrate with the conducting polymer poly(3-octylthiophene) (POT) electrodeposited on it and a potassium-selective nanomembrane spin-coated over the POT layer. The K<sup>+</sup> transfer at the membrane-sample interface is mediated by the redox activity of POT, which is in excess with respect to the dopant in the membrane (i.e., the anion part of the cation exchanger, R<sup>-</sup>). In the cathodic protocol, the entry of the K<sup>+</sup> into the membrane is promoted by the POT<sup>+</sup> reduction to POT<sup>0</sup>; while in the anodic interrogation, first, K<sup>+</sup> enters the membrane with a previous accumulation step, and then it is expelled during the oxidation of the POT<sup>0</sup> to POT<sup>+</sup>. Both protocols were studied under linear sweep voltammetry and chronoamperometry, followed by signal integration to obtain the charge corresponding to K<sup>+</sup>. It is demonstrated that this charge is directly proportional to the K<sup>+</sup> concentration in the bulk solution. We found two distinct response ranges: 3-20 μM in the cathodic protocol and 200-1000 nM in the anodic one. In addition, the cathodic coulometry strategy revealed excellent repeatability and reversibility within the linear range of response. The developed analytical approach demonstrates suitability in the quantification of real samples, i.e., human urine, horse serum, canal water, and standard KCl solution, while providing a linear and tunable coulometric response over a broad concentration range from the nanomolar to the micromolar level. Moreover, the sensor can be readily integrated into microfluidic devices, additionally offering the advantage of small sample volume requirements. The demonstrated reversibility, along with the ability to customize the ionophore in the membrane for an analysis of different ions, renders the proposed concept adaptable and exceptionally suitable for clinical analysis and environmental monitoring.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-02-02
DOI
https://doi.org/10.1021/acs.analchem.5c07283
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tunable Ion-Sensing Using Coulometric-Based Protocols with Permselective Nanomembranes

Y. Liu, Gregorio Laucirica, Gastón A. Crespo, Nuria Martínez-Lorca et al.
Analytical Chemistry
Analytical Chemistry and Sensors
article

Tunable Ion-Sensing Using Coulometric-Based Protocols with Permselective Nanomembranes

Y. Liu, Gregorio Laucirica, Gastón A. Crespo, Nuria Martínez-Lorca, María Cuartero
article en

Abstract

Herein, we investigate all-solid-state ion-selective electrodes (ISEs) based on permselective nanomembranes (thickness ∼230 nm) in a coulometric mode. The detection of the potassium ion (K<sup>+</sup>) has been selected as proof of concept, implementing two electrochemical protocols based on the anodic and cathodic readouts of the same ISE. The electrode consists of an ITO glass substrate with the conducting polymer poly(3-octylthiophene) (POT) electrodeposited on it and a potassium-selective nanomembrane spin-coated over the POT layer. The K<sup>+</sup> transfer at the membrane-sample interface is mediated by the redox activity of POT, which is in excess with respect to the dopant in the membrane (i.e., the anion part of the cation exchanger, R<sup>-</sup>). In the cathodic protocol, the entry of the K<sup>+</sup> into the membrane is promoted by the POT<sup>+</sup> reduction to POT<sup>0</sup>; while in the anodic interrogation, first, K<sup>+</sup> enters the membrane with a previous accumulation step, and then it is expelled during the oxidation of the POT<sup>0</sup> to POT<sup>+</sup>. Both protocols were studied under linear sweep voltammetry and chronoamperometry, followed by signal integration to obtain the charge corresponding to K<sup>+</sup>. It is demonstrated that this charge is directly proportional to the K<sup>+</sup> concentration in the bulk solution. We found two distinct response ranges: 3-20 μM in the cathodic protocol and 200-1000 nM in the anodic one. In addition, the cathodic coulometry strategy revealed excellent repeatability and reversibility within the linear range of response. The developed analytical approach demonstrates suitability in the quantification of real samples, i.e., human urine, horse serum, canal water, and standard KCl solution, while providing a linear and tunable coulometric response over a broad concentration range from the nanomolar to the micromolar level. Moreover, the sensor can be readily integrated into microfluidic devices, additionally offering the advantage of small sample volume requirements. The demonstrated reversibility, along with the ability to customize the ionophore in the membrane for an analysis of different ions, renders the proposed concept adaptable and exceptionally suitable for clinical analysis and environmental monitoring.

Analytical ChemistryVol. 98(6)
Universidad Católica de Murcia (ES), KTH Royal Institute of Technology (SE)
Clean water and sanitation
Openalex Percentile: Top 70%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.