Comparative Elemental Signatures of Full Metal Jacket (FMJ) and Lead Round Nose (LRN) Projectiles on Complex Biological Targets Using Micro-XRF and Portable XRF

Background: In forensic ballistics, identifying ammunition types on physical evidence is critical, particularly when metallic residues are minimal. This study comparatively analyzes the elemental signatures deposited by two common projectiles—Full Metal Jacket (FMJ) (Cu/Zn jacket) and Lead Round Nose (LRN) (exposed Pb core)—on complex targets, including pig bone/tissue and mango wood. Methods: Using a semi-automatic handgun at an intermediate range of 5.0 m, residues were examined through high-resolution benchtop Micro-XRF (M4 Tornado) for micro-spatial analysis and Portable XRF (Elio) for rapid field characterization. Additionally, fresh pork leg samples were subjected to a 3-month environmental degradation period to assess trace persistence. Results: Observations indicated that LRN projectiles exhibit markedly elevated Lead (Pb) concentrations along the wound track in bone, hence confirming Pb as a reliable indicator for unjacketed ammunition; specifically, the median Pb concentrations at bullet wiping were 10.39 wt% for M4 and 7.34 wt% for Elio. Conversely, FMJ traces remain strictly confined to the surface bullet wipe area, with median concentrations of Pb, Cu, and Zn being 2.21 wt%, 0.24 wt%, and 0.59 wt% via M4, respectively. Statistical analysis showed a strong correlation for high-concentration elements on tissue, but significantly greater variance on wooden surfaces where FMJ traces exhibited a very weak negative correlation (r = −0.2774) due to minimal and irregular metal transfer. Taphonomic evaluation revealed that the Pb signature from LRN is exceptionally stable (r ≈ 0.9999) even after decomposition, while FMJ signatures are highly sensitive to environmental exposure. Conclusions: This research underscores the necessity of high-sensitivity Micro-XRF (M4) for definitive ammunition verification, providing a refined analytical framework for shooting incident reconstruction even involving degraded remains or complex environmental scenes.

Authors

Institutions

Publication Details

Journal
Forensic Sciences
Published
2026-02-02
DOI
https://doi.org/10.3390/forensicsci6010011
Primary Topic
Forensic and Genetic Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Elemental Signatures of Full Metal Jacket (FMJ) and Lead Round Nose (LRN) Projectiles on Complex Biological Targets Using Micro-XRF and Portable XRF

M. Donphoongpri, Suthisa Leasen, Panida Lorwongtragool, Sittichoke Chaiwan
Forensic Sciences
Forensic and Genetic Research
article

Comparative Elemental Signatures of Full Metal Jacket (FMJ) and Lead Round Nose (LRN) Projectiles on Complex Biological Targets Using Micro-XRF and Portable XRF

M. Donphoongpri, Suthisa Leasen, Panida Lorwongtragool, Sittichoke Chaiwan
article en

Abstract

Background: In forensic ballistics, identifying ammunition types on physical evidence is critical, particularly when metallic residues are minimal. This study comparatively analyzes the elemental signatures deposited by two common projectiles—Full Metal Jacket (FMJ) (Cu/Zn jacket) and Lead Round Nose (LRN) (exposed Pb core)—on complex targets, including pig bone/tissue and mango wood. Methods: Using a semi-automatic handgun at an intermediate range of 5.0 m, residues were examined through high-resolution benchtop Micro-XRF (M4 Tornado) for micro-spatial analysis and Portable XRF (Elio) for rapid field characterization. Additionally, fresh pork leg samples were subjected to a 3-month environmental degradation period to assess trace persistence. Results: Observations indicated that LRN projectiles exhibit markedly elevated Lead (Pb) concentrations along the wound track in bone, hence confirming Pb as a reliable indicator for unjacketed ammunition; specifically, the median Pb concentrations at bullet wiping were 10.39 wt% for M4 and 7.34 wt% for Elio. Conversely, FMJ traces remain strictly confined to the surface bullet wipe area, with median concentrations of Pb, Cu, and Zn being 2.21 wt%, 0.24 wt%, and 0.59 wt% via M4, respectively. Statistical analysis showed a strong correlation for high-concentration elements on tissue, but significantly greater variance on wooden surfaces where FMJ traces exhibited a very weak negative correlation (r = −0.2774) due to minimal and irregular metal transfer. Taphonomic evaluation revealed that the Pb signature from LRN is exceptionally stable (r ≈ 0.9999) even after decomposition, while FMJ signatures are highly sensitive to environmental exposure. Conclusions: This research underscores the necessity of high-sensitivity Micro-XRF (M4) for definitive ammunition verification, providing a refined analytical framework for shooting incident reconstruction even involving degraded remains or complex environmental scenes.

Forensic SciencesVol. 6(1)
Rajamangala University of Technology Isan (TH), Institute of Forensic Science (CN), Silpakorn University (TH)
Life in Land
Openalex Percentile: Top 66%
Forensic and Genetic Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.