Dual-channel single-spectrometer chromatic confocal coherence sensing to mitigate bandwidth compression in film thickness and refractive-index measurement

A dual-channel single-spectrometer chromatic confocal coherence sensor is proposed for simultaneous measurement of film thickness and refractive index. Compared with the conventional single-channel single-spectrometer approach, the proposed method converts the multiplicative coupling between interferometric and confocal signals into an additive form by introducing an additional detection channel and eliminating the need for an external reference arm. As a result, the optical thickness resolution is improved by one order of magnitude. For validation, a sensor system is established, and film specimens with different materials and thicknesses are measured. The results demonstrate that the dual-channel configuration introduces no additional structural complexity while improving the optical thickness resolution from 50 µm to 5 µm, with film thickness and refractive-index measurement errors less than 11 µm and 0.02, respectively.

Authors

Publication Details

Journal
Optics Letters
Published
2026-02-02
DOI
https://doi.org/10.1364/ol.588564
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-channel single-spectrometer chromatic confocal coherence sensing to mitigate bandwidth compression in film thickness and refractive-index measurement

YuLei BAI, Guanggao Zhou, Bo Dong, Shengli Xie
Optics Letters
Optical Coherence Tomography Applications
article

Dual-channel single-spectrometer chromatic confocal coherence sensing to mitigate bandwidth compression in film thickness and refractive-index measurement

YuLei BAI, Guanggao Zhou, Bo Dong, Shengli Xie
article en

Abstract

A dual-channel single-spectrometer chromatic confocal coherence sensor is proposed for simultaneous measurement of film thickness and refractive index. Compared with the conventional single-channel single-spectrometer approach, the proposed method converts the multiplicative coupling between interferometric and confocal signals into an additive form by introducing an additional detection channel and eliminating the need for an external reference arm. As a result, the optical thickness resolution is improved by one order of magnitude. For validation, a sensor system is established, and film specimens with different materials and thicknesses are measured. The results demonstrate that the dual-channel configuration introduces no additional structural complexity while improving the optical thickness resolution from 50 µm to 5 µm, with film thickness and refractive-index measurement errors less than 11 µm and 0.02, respectively.

Optics LettersVol. 51(5)
Openalex Percentile: Top 70%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.