Non-inertial scan angle multiplier for expanded fields-of-view

In many laser scan engines, mechanical inertia imposes a tradeoff between mirror diameter (mass) and scan speed (cycle time) and/or scan angle amplitude. Ultimately, this limits the field-of-view and/or scan speed in multiphoton and confocal imaging, laser-based manufacturing, and other applications. To push parameters past this inertia limit, we present a non-inertial (stationary) add-on unit that doubles the scan angle amplitude while preserving both the beam size and cycle time, thus doubling the étendue (optical invariant) and overall system throughput. We demonstrate its use in two-photon calcium imaging of neural activity in living mice. We also adapt the approach to present a phase-doubling unit that doubles the maximum range of phase modulators. Finally, we describe further variants, including generalizing the approach to Nx scan angle multiplication (N=2,3,4,…) with diffraction-limited performance across a wide scan angle range and over a broad wavelength bandwidth. These non-inertial scan angle multipliers (called Nisam2x, 3x,…) fundamentally break the inertia-imposed tether between scan speed and scan angle amplitude, enabling expanded capabilities of a range of technologies, including imaging, adaptive optics, sensing, marking, and manufacturing.

Authors

Publication Details

Journal
Optica
Published
2026-02-02
DOI
https://doi.org/10.1364/optica.570761
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-inertial scan angle multiplier for expanded fields-of-view

Joseph S. Canzano, Yaolin Fei, Filip Tomáška, Che-Hang Yu et al.
Optica
Optical measurement and interference techniques
article

Non-inertial scan angle multiplier for expanded fields-of-view

Joseph S. Canzano, Yaolin Fei, Filip Tomáška, Che-Hang Yu, Yiyi Yu, Spencer Smith
article en

Abstract

In many laser scan engines, mechanical inertia imposes a tradeoff between mirror diameter (mass) and scan speed (cycle time) and/or scan angle amplitude. Ultimately, this limits the field-of-view and/or scan speed in multiphoton and confocal imaging, laser-based manufacturing, and other applications. To push parameters past this inertia limit, we present a non-inertial (stationary) add-on unit that doubles the scan angle amplitude while preserving both the beam size and cycle time, thus doubling the étendue (optical invariant) and overall system throughput. We demonstrate its use in two-photon calcium imaging of neural activity in living mice. We also adapt the approach to present a phase-doubling unit that doubles the maximum range of phase modulators. Finally, we describe further variants, including generalizing the approach to Nx scan angle multiplication (N=2,3,4,…) with diffraction-limited performance across a wide scan angle range and over a broad wavelength bandwidth. These non-inertial scan angle multipliers (called Nisam2x, 3x,…) fundamentally break the inertia-imposed tether between scan speed and scan angle amplitude, enabling expanded capabilities of a range of technologies, including imaging, adaptive optics, sensing, marking, and manufacturing.

OpticaVol. 13(3)
Affordable and clean energy
Openalex Percentile: Top 72%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.