High-Sensitivity Microwave Resonator Sensor for Aqueous Glucose Detection Using Field-Concentrating Elements

In this study, we present a highly sensitive microwave sensor for determining the concentration of aqueous glucose solutions in the microwave regime. The proposed sensor is based on a single split-ring resonator (SRR) printed on a Rogers RO3003 substrate and operates at 2.9 GHz. The sensitivity of this sensor is enhanced by using a narrow gap of approximately 100 μm, which increases the capacitance of the SRR and, more importantly, produces a localized field enhancement within the gap region. Moreover, the proposed design operates with only 2 μL of sample, a notable improvement over sensors that typically require larger liquid volumes. Both the simulation and measurement results showed a clear linear shift in the resonance frequency over a concentration range of 0-400 mg/dL, with the ability to detect minimal concentration variations as small as 50 mg/dL. These results confirm the effectiveness of the sensor for noninvasive glucose detection and represent a significant advancement in the field of microwave sensing.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2026-02-02
DOI
https://doi.org/10.1109/jsen.2026.3658569
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Sensitivity Microwave Resonator Sensor for Aqueous Glucose Detection Using Field-Concentrating Elements

Mariem Aznabet, Luis Jofre-Roca, Fatima Ataa Allah, Jordi Romeu-Robert et al.
IEEE Sensors Journal
Microwave and Dielectric Measurement Techniques
article

High-Sensitivity Microwave Resonator Sensor for Aqueous Glucose Detection Using Field-Concentrating Elements

Mariem Aznabet, Luis Jofre-Roca, Fatima Ataa Allah, Jordi Romeu-Robert, Houda Ataa Allah, Otman EL Mrabet
article en

Abstract

In this study, we present a highly sensitive microwave sensor for determining the concentration of aqueous glucose solutions in the microwave regime. The proposed sensor is based on a single split-ring resonator (SRR) printed on a Rogers RO3003 substrate and operates at 2.9 GHz. The sensitivity of this sensor is enhanced by using a narrow gap of approximately 100 μm, which increases the capacitance of the SRR and, more importantly, produces a localized field enhancement within the gap region. Moreover, the proposed design operates with only 2 μL of sample, a notable improvement over sensors that typically require larger liquid volumes. Both the simulation and measurement results showed a clear linear shift in the resonance frequency over a concentration range of 0-400 mg/dL, with the ability to detect minimal concentration variations as small as 50 mg/dL. These results confirm the effectiveness of the sensor for noninvasive glucose detection and represent a significant advancement in the field of microwave sensing.

IEEE Sensors JournalVol. 26(6)
Abdelmalek Essaâdi University (MA), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 69%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.