Enhancing laboratory quality through comprehensive risk management and process analysis

BackgroundLaboratory test results are crucial for clinical decisions, but errors at any stage can compromise patient safety. Despite technological advances and quality systems, laboratory processes remain vulnerable, necessitating structured risk assessment. Limited research exists on integrating Failure Mode and Effects Analysis (FMEA) with Sigma metrics. This study addresses these gaps through a comprehensive risk assessment in a NABL-accredited tertiary care hospital laboratory.MethodsA retrospective observational study was conducted over 2.5 years. FMEA was used to identify errors across all phases of the total testing process. Quarterly error rates were calculated, converted to defects per million (DPM), and expressed as Sigma metrics. Risk Priority Numbers (RPN = severity × detectability × frequency) were scored quarterly to prioritize failures. The effect of corrective actions was evaluated by comparing pre- and post-intervention Sigma values.ResultsAcross 10 quarters (five pre- and five post-intervention), 23 error types were identified. The highest RPNs (>20) were observed for haemolyzed samples, clotted samples, and non-intimation of critical values. Haemolyzed samples declined from 0.97% to 0.49% (ARR 0.48%; RR 0.51; 95% CI 0.47-0.55; <i>P</i> < .0001). Clotted samples reduced from 0.24% to 0.06% (ARR 0.18%; RR 0.24; 95% CI 0.20-0.29; <i>P</i> < .0001). Non-intimation of critical values decreased from 2.63% to 2.18% (RR 0.83; 95% CI 0.70-0.99; <i>P</i> = .065).ConclusionIntegrating FMEA with Sigma metrics provides a robust framework for identifying, prioritizing, and reducing laboratory errors. Continuous monitoring and corrective action are essential to sustain improvements in laboratory quality and patient safety.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2026-02-02
DOI
https://doi.org/10.1177/00045632261424771
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing laboratory quality through comprehensive risk management and process analysis

Ramesh Kumar, Shobha Chikkavaddaragudi Ramachandra, Akila Prashant, Swetha N Kempegowda et al.
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Clinical Laboratory Practices and Quality Control
article

Enhancing laboratory quality through comprehensive risk management and process analysis

Ramesh Kumar, Shobha Chikkavaddaragudi Ramachandra, Akila Prashant, Swetha N Kempegowda, Kusuma K Shivashankar, Venkatesha Madegowda
article en

Abstract

BackgroundLaboratory test results are crucial for clinical decisions, but errors at any stage can compromise patient safety. Despite technological advances and quality systems, laboratory processes remain vulnerable, necessitating structured risk assessment. Limited research exists on integrating Failure Mode and Effects Analysis (FMEA) with Sigma metrics. This study addresses these gaps through a comprehensive risk assessment in a NABL-accredited tertiary care hospital laboratory.MethodsA retrospective observational study was conducted over 2.5 years. FMEA was used to identify errors across all phases of the total testing process. Quarterly error rates were calculated, converted to defects per million (DPM), and expressed as Sigma metrics. Risk Priority Numbers (RPN = severity × detectability × frequency) were scored quarterly to prioritize failures. The effect of corrective actions was evaluated by comparing pre- and post-intervention Sigma values.ResultsAcross 10 quarters (five pre- and five post-intervention), 23 error types were identified. The highest RPNs (>20) were observed for haemolyzed samples, clotted samples, and non-intimation of critical values. Haemolyzed samples declined from 0.97% to 0.49% (ARR 0.48%; RR 0.51; 95% CI 0.47-0.55; <i>P</i> < .0001). Clotted samples reduced from 0.24% to 0.06% (ARR 0.18%; RR 0.24; 95% CI 0.20-0.29; <i>P</i> < .0001). Non-intimation of critical values decreased from 2.63% to 2.18% (RR 0.83; 95% CI 0.70-0.99; <i>P</i> = .065).ConclusionIntegrating FMEA with Sigma metrics provides a robust framework for identifying, prioritizing, and reducing laboratory errors. Continuous monitoring and corrective action are essential to sustain improvements in laboratory quality and patient safety.

Annals of Clinical Biochemistry International Journal of Laboratory Medicine
JSS Academy of Higher Education and Research (IN)
Openalex Percentile: Top 69%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.