Single-Center, Open-Label, Randomized Controlled Trial on the Reduction of Scattered Radiation Exposure to the Primary Operator in Radial, Femoral, and Pectoral Cath Lab Procedures Using a Radiation Protection Drape

Radiation exposure in the catheterization laboratory poses a significant occupational hazard for primary operators. This single-center, open-label, randomized controlled trial conducted at Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, evaluated scattered radiation exposure to the primary operator during procedures via radial, femoral, and pectoral vascular access sites and the effectiveness of radiation protection drapes in reducing this exposure. A total of 216 patients (72 in each vascular access group) were randomized using coin flipping to receive either standard radiation protection or additional shielding with a radiation protection drape. The primary operator's scattered radiation dose was assessed in comparison to the radiation emitted during the procedure, with normalization to procedural radiation parameters including air kerma (AK), dose area product (DAP), and cine-adjusted screen time (CAST). Pectoral access was associated with the highest operator exposure (96.75 µSv) compared to femoral (45.72 µSv) and radial (49.06 µSv) access, despite lower AK values. Radiation protection drapes significantly reduced operator exposure across all access sites, with radial access showing reductions of 51% (DAP), 48% (AK), and 53% (CAST); femoral access showing reductions of 82% (DAP), 74% (AK), and 63% (CAST); and pectoral access showing reductions of 62% (DAP), 49% (AK), and 52% (CAST), all statistically significant (P < 0.05). No adverse events were reported. The findings provide strong support for the routine use of radiation protection drapes to minimize primary operator radiation exposure during catheterization procedures, especially when using the pectoral access site.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-02-02
DOI
https://doi.org/10.1097/hp.0000000000002100
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-Center, Open-Label, Randomized Controlled Trial on the Reduction of Scattered Radiation Exposure to the Primary Operator in Radial, Femoral, and Pectoral Cath Lab Procedures Using a Radiation Protection Drape

Shodhan Aithal, Puneet Kumar Gupta, Zubair Farooq, Sandeep Bansal et al.
Health Physics
Radiation Dose and Imaging
article

Single-Center, Open-Label, Randomized Controlled Trial on the Reduction of Scattered Radiation Exposure to the Primary Operator in Radial, Femoral, and Pectoral Cath Lab Procedures Using a Radiation Protection Drape

Shodhan Aithal, Puneet Kumar Gupta, Zubair Farooq, Sandeep Bansal, Hermohander Singh Isser
article en

Abstract

Radiation exposure in the catheterization laboratory poses a significant occupational hazard for primary operators. This single-center, open-label, randomized controlled trial conducted at Vardhman Mahavir Medical College and Safdarjung Hospital, New Delhi, evaluated scattered radiation exposure to the primary operator during procedures via radial, femoral, and pectoral vascular access sites and the effectiveness of radiation protection drapes in reducing this exposure. A total of 216 patients (72 in each vascular access group) were randomized using coin flipping to receive either standard radiation protection or additional shielding with a radiation protection drape. The primary operator's scattered radiation dose was assessed in comparison to the radiation emitted during the procedure, with normalization to procedural radiation parameters including air kerma (AK), dose area product (DAP), and cine-adjusted screen time (CAST). Pectoral access was associated with the highest operator exposure (96.75 µSv) compared to femoral (45.72 µSv) and radial (49.06 µSv) access, despite lower AK values. Radiation protection drapes significantly reduced operator exposure across all access sites, with radial access showing reductions of 51% (DAP), 48% (AK), and 53% (CAST); femoral access showing reductions of 82% (DAP), 74% (AK), and 63% (CAST); and pectoral access showing reductions of 62% (DAP), 49% (AK), and 52% (CAST), all statistically significant (P < 0.05). No adverse events were reported. The findings provide strong support for the routine use of radiation protection drapes to minimize primary operator radiation exposure during catheterization procedures, especially when using the pectoral access site.

Health Physics
Vardhman Mahavir Medical College & Safdarjung Hospital (IN)
Good health and well-being
Openalex Percentile: Top 70%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.