1,000-fold amplification in time-holography phase metrology

Conventional interferometers provide uniform phase sensitivity across the measurement range. However, for applications involving small phase changes, amplifying the response within a specific phase range—at the expense of reduced sensitivity elsewhere—can be advantageous. A key example is the Gires-Tournois etalon, used in gravitational wave interferometers. In this work, we introduce an ultrasensitive phase measurement system based on time-holographic recording with a conventional Mach-Zehnder interferometer, operated near the intensity minimum at the dark output port. Phase fluctuations in the milliradian range around this point are converted into rad-sized dark output phases, with amplification factors exceeding 1,000. The adjustable imbalance between the interferometer arms controls this magnification, which is revealed by heterodyning the output with a frequency-shifted beam. Phase is digitally retrieved from the time-hologram using Fourier processing, with noise subtraction for correction. The system achieves phase sensitivities better than λ/3,000, enabling sub-nanometer precision for dimensional measurements. This versatile platform provides powerful tools for ultrasensitive phase measurements in a wide range of scientific and technological applications.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-09-22
DOI
https://doi.org/10.1051/epjconf/202533501002/pdf
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1,000-fold amplification in time-holography phase metrology

Germán J. de Valcárcel, A. Esteban-Martín, José Angel Picazo Bueno, Fernando Silva et al.
Springer Link (Chiba Institute of Technology)
Digital Holography and Microscopy
article

1,000-fold amplification in time-holography phase metrology

Germán J. de Valcárcel, A. Esteban-Martín, José Angel Picazo Bueno, Fernando Silva, Andreu Molina-García, Javier García-Monreal
article en

Abstract

Conventional interferometers provide uniform phase sensitivity across the measurement range. However, for applications involving small phase changes, amplifying the response within a specific phase range—at the expense of reduced sensitivity elsewhere—can be advantageous. A key example is the Gires-Tournois etalon, used in gravitational wave interferometers. In this work, we introduce an ultrasensitive phase measurement system based on time-holographic recording with a conventional Mach-Zehnder interferometer, operated near the intensity minimum at the dark output port. Phase fluctuations in the milliradian range around this point are converted into rad-sized dark output phases, with amplification factors exceeding 1,000. The adjustable imbalance between the interferometer arms controls this magnification, which is revealed by heterodyning the output with a frequency-shifted beam. Phase is digitally retrieved from the time-hologram using Fourier processing, with noise subtraction for correction. The system achieves phase sensitivities better than λ/3,000, enabling sub-nanometer precision for dimensional measurements. This versatile platform provides powerful tools for ultrasensitive phase measurements in a wide range of scientific and technological applications.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 28%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.