Processor In the Loop implementation of two stages Backstepping control strategy for Permanent Magnet Synchronous Motor based load torque observer

This work deals with Backstepping control strategy for permanent magnet synchronous motor drive, using load torque observer. The proposed study uses a modified motor model with new variables, dynamic separation and Luenberger load torque observer. This paper proposes a precise calculation method for controller and observer parameters based on response time and damping coefficient. Validation is performed using Processor In the Loop technique and code generation from Simulink. Results show that Backstepping works well by adding disturbance observer so accuracy is ensured. In addition, response time is respected due to the precise controller design.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-06-30
DOI
https://doi.org/10.1051/epjconf/202533002009/pdf
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Processor In the Loop implementation of two stages Backstepping control strategy for Permanent Magnet Synchronous Motor based load torque observer

Mohammed El Haissouf, Mounir Bensaid, Mustapha Elharoussi, A. Ba-Razzouk
Springer Link (Chiba Institute of Technology)
Sensorless Control of Electric Motors
article

Processor In the Loop implementation of two stages Backstepping control strategy for Permanent Magnet Synchronous Motor based load torque observer

Mohammed El Haissouf, Mounir Bensaid, Mustapha Elharoussi, A. Ba-Razzouk
article en

Abstract

This work deals with Backstepping control strategy for permanent magnet synchronous motor drive, using load torque observer. The proposed study uses a modified motor model with new variables, dynamic separation and Luenberger load torque observer. This paper proposes a precise calculation method for controller and observer parameters based on response time and damping coefficient. Validation is performed using Processor In the Loop technique and code generation from Simulink. Results show that Backstepping works well by adding disturbance observer so accuracy is ensured. In addition, response time is respected due to the precise controller design.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 37%
Sensorless Control of Electric Motors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Processor In the Loop implementation of two stages Backstepping control strategy for Permanent Magnet Synchronous Motor based load torque observer — Mohammed El Haissouf, Mounir Bensaid, et al. · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS