Zero-Voltage-Switching Buck Converter Using Digital Hybrid Control with Variable Slope Compensation

This paper proposes a zero-voltage-switching (ZVS) synchronous buck converter employing a digital hybrid control scheme with variable slope compensation. By using an auxiliary-switch network and a digital controller to sense voltage and current, the system can automatically adjust the slope-compensation parameters according to the input and output conditions, thereby enhancing stability over a wide operating range. The proposed method effectively suppresses the reverse-recovery current spike of the synchronous rectifier during continuous conduction mode (CCM) operation and enables the main switch to achieve ZVS, reducing switching loss and improving efficiency. A laboratory prototype with an input voltage range of 30–160 V and output voltage levels of 24 V, 48 V, and 96 V at 5 A is developed to verify the feasibility of the proposed architecture.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-02-02
DOI
https://doi.org/10.3390/electronics15030654
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zero-Voltage-Switching Buck Converter Using Digital Hybrid Control with Variable Slope Compensation

Ming-Tsung Tsai, Wen-Chuan Fang, Yu-Jui Chen, Ching-Lung Chu
Electronics
Advanced DC-DC Converters
article

Zero-Voltage-Switching Buck Converter Using Digital Hybrid Control with Variable Slope Compensation

Ming-Tsung Tsai, Wen-Chuan Fang, Yu-Jui Chen, Ching-Lung Chu
article en

Abstract

This paper proposes a zero-voltage-switching (ZVS) synchronous buck converter employing a digital hybrid control scheme with variable slope compensation. By using an auxiliary-switch network and a digital controller to sense voltage and current, the system can automatically adjust the slope-compensation parameters according to the input and output conditions, thereby enhancing stability over a wide operating range. The proposed method effectively suppresses the reverse-recovery current spike of the synchronous rectifier during continuous conduction mode (CCM) operation and enables the main switch to achieve ZVS, reducing switching loss and improving efficiency. A laboratory prototype with an input voltage range of 30–160 V and output voltage levels of 24 V, 48 V, and 96 V at 5 A is developed to verify the feasibility of the proposed architecture.

ElectronicsVol. 15(3)
Southern Taiwan University of Science and Technology (TW)
National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 69%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.