Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?

Short-stem total hip arthroplasty (THA) has gained popularity due to its bone-preserving properties and improved physiological load transmission to the proximal femur. Despite these advantages, the ability of short-stem implants to reliably restore leg length and offset remains debated. This study evaluates whether a single offset implant is sufficient for accurate anatomical reconstruction or if multiple offset options are necessary. A total of 148 anteroposterior pelvic radiographs of patients scheduled for short-stem THA were analysed using MediCAD® software. Femoral offset and leg length were measured, and the accuracy of anatomical reconstruction was assessed within a 5-mm target range. Comparisons were made between a single offset (130°) implant and a dual-offset system (130° and 119°) using the McNemar-Bowker test. With a single 130° CCD (Caput-collum-diaphyseal) offset implant, 55.7% (82/148) of cases achieved satisfactory leg length and offset restoration. The use of a dual-offset system improved accuracy to 79.1% (117/148), demonstrating a statistically significant advantage (p < 0.001). The study highlights the need for at least two CCD-angle-offset combinations in short-stem THA to address anatomical variability. A dual-offset system enhances accuracy, reduces biomechanical imbalances, and therefore we expect improvements in clinical outcomes, particularly in teaching hospitals where standardization is essential.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-02-02
DOI
https://doi.org/10.1007/s00402-026-06194-7
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?

Hagen Mittelstädt, Bernd Bittersohl, Christoph Zilkens, J. Babisch et al.
Archives of Orthopaedic and Trauma Surgery
Orthopaedic implants and arthroplasty
article

Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?

Hagen Mittelstädt, Bernd Bittersohl, Christoph Zilkens, J. Babisch, Rüdiger Krauspe, Marcus Jäger, Felix Olk
article en

Abstract

Short-stem total hip arthroplasty (THA) has gained popularity due to its bone-preserving properties and improved physiological load transmission to the proximal femur. Despite these advantages, the ability of short-stem implants to reliably restore leg length and offset remains debated. This study evaluates whether a single offset implant is sufficient for accurate anatomical reconstruction or if multiple offset options are necessary. A total of 148 anteroposterior pelvic radiographs of patients scheduled for short-stem THA were analysed using MediCAD® software. Femoral offset and leg length were measured, and the accuracy of anatomical reconstruction was assessed within a 5-mm target range. Comparisons were made between a single offset (130°) implant and a dual-offset system (130° and 119°) using the McNemar-Bowker test. With a single 130° CCD (Caput-collum-diaphyseal) offset implant, 55.7% (82/148) of cases achieved satisfactory leg length and offset restoration. The use of a dual-offset system improved accuracy to 79.1% (117/148), demonstrating a statistically significant advantage (p < 0.001). The study highlights the need for at least two CCD-angle-offset combinations in short-stem THA to address anatomical variability. A dual-offset system enhances accuracy, reduces biomechanical imbalances, and therefore we expect improvements in clinical outcomes, particularly in teaching hospitals where standardization is essential.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
Raumedic (Germany) (DE), University Hospital Schleswig-Holstein (DE), Klinikum Bielefeld (DE), Lukaskrankenhaus (DE), Helios Klinikum Erfurt (DE), Heinrich Heine University Düsseldorf (DE), University of Duisburg-Essen (DE), University of Lübeck (DE)
Openalex Percentile: Top 69%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.