GIS isolation switch contact temperature wireless monitoring

The contact temperature of GIS is an indicator that reflects contact fault information and requires real-time monitoring. There is currently no direct installation of sensors to monitor temperature. Therefore, this article proposes using multi-point temperature monitoring values on the outer shell to invert and calculate the internal temperature of GIS. In addition, the multi-point sensor on the casing has been optimized. Firstly, a finite element analysis model for the temperature field of the 500kV isolation switch chamber was established, analyzed the distribution of temperature field. The installation position of the sensor on the outer shell was determined. At the same time, conduct temperature rise tests and compare the test results with the simulation results to prove the accuracy of the simulation model. Then, SVR is used to train the correspondence between multiple temperatures of the casing, contact temperature, and external temperature. The measurement of the temperature on the shell multiplied by the ambient temperature is used for the conversion calculation of contact temperature. It was found that the average absolute error of monitoring is 0.47%. This method can save economic costs and achieve the required accuracy for engineering applications.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-07-04
DOI
https://doi.org/10.1051/shsconf/202521902007/pdf
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GIS isolation switch contact temperature wireless monitoring

Yubo Zhao, J Y Zhang, jiuye Zhang, Liang Wang et al.
Springer Link (Chiba Institute of Technology)
Thermal Analysis in Power Transmission
article

GIS isolation switch contact temperature wireless monitoring

Yubo Zhao, J Y Zhang, jiuye Zhang, Liang Wang, Haoli Liu, Jiaqi Li
article en

Abstract

The contact temperature of GIS is an indicator that reflects contact fault information and requires real-time monitoring. There is currently no direct installation of sensors to monitor temperature. Therefore, this article proposes using multi-point temperature monitoring values on the outer shell to invert and calculate the internal temperature of GIS. In addition, the multi-point sensor on the casing has been optimized. Firstly, a finite element analysis model for the temperature field of the 500kV isolation switch chamber was established, analyzed the distribution of temperature field. The installation position of the sensor on the outer shell was determined. At the same time, conduct temperature rise tests and compare the test results with the simulation results to prove the accuracy of the simulation model. Then, SVR is used to train the correspondence between multiple temperatures of the casing, contact temperature, and external temperature. The measurement of the temperature on the shell multiplied by the ambient temperature is used for the conversion calculation of contact temperature. It was found that the average absolute error of monitoring is 0.47%. This method can save economic costs and achieve the required accuracy for engineering applications.

Springer Link (Chiba Institute of Technology)
Decent work and economic growth
Openalex Percentile: Top 31%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.