Assessing the Diagnostic Accuracy of BiomedCLIP for Detecting Contrast Use and Esophageal Strictures in Pediatric Radiography
<b>Background/Objectives</b>: Vision-language models such as BiomedCLIP are increasingly investigated for their diagnostic potential in medical imaging. Although these foundation models show promise in general radiographic interpretation, their application in pediatric domains-particularly for subtle, postoperative findings like esophageal strictures-remains underexplored. This study aimed to evaluate the diagnostic performance of BiomedCLIP in classifying pediatric esophageal radiographs into three clinically relevant categories: presence of contrast agent, full esophageal visibility, and presence of esophageal stricture. <b>Methods</b>: We retrospectively analyzed 143 pediatric esophageal X-rays collected between 2021 and 2025. Each image was annotated by two pediatric radiology experts and categorized according to esophageal visibility, contrast presence, and stricture occurrence. BiomedCLIP was used in a zero-shot classification setup without fine-tuning. Model predictions were converted into binary outcomes and assessed against the ground truth using a comprehensive suite of 27 performance metrics, including accuracy, sensitivity, specificity, F1-score, AUC, and calibration analyses. <b>Results</b>: BiomedCLIP achieved high precision (88.7%) and a favorable AUC (85.4%) in detecting contrast agent presence, though specificity remained low (20%), leading to a high false-positive rate. The model correctly identified all cases of non-visible esophagus, but was untestable in predicting full visibility due to the absence of positive cases. Critically, its performance in detecting esophageal strictures was poor, with accuracy at 24%, sensitivity at 44%, specificity at 18%, and AUC of 0.26. Statistical overlap between contrast and stricture predictions indicated a lack of semantic differentiation within the model's latent space. <b>Conclusions</b>: BiomedCLIP shows potential in detecting high-salience features such as contrast but fails to reliably identify esophageal strictures. Limitations include class imbalance, absence of fine-tuning, and architectural constraints in recognizing subtle morphologic abnormalities. These findings emphasize the need for domain-specific adaptation of foundation models before clinical implementation in pediatric radiology.
Authors
- Michał Kolejwa (ORCID: https://orcid.org/0000-0001-5137-3251)
- Agnieszka Zawadzka-Fabijan (ORCID: https://orcid.org/0000-0002-4031-0930)
- Anna Socha‐Banasiak (ORCID: https://orcid.org/0000-0002-3690-6328)
- Elżbieta Czkwianianc (ORCID: https://orcid.org/0000-0002-0384-2049)
- Artur Fabijan (ORCID: https://orcid.org/0000-0002-0998-4435)
- Robert Fabijan
- Róża Kosińska
- Marcin Tkaczyk
- Natalia Lwow
- Emilia Nowosławska
- Bartosz Polis
Institutions
- Medical University of Lodz (PL)
- Polish Mother’s Memorial Hospital Research Institute (PL)
Publication Details
- Journal
- Journal of Clinical Medicine
- Published
- 2026-02-02
- DOI
- https://doi.org/10.3390/jcm15031150
- Primary Topic
- Esophageal and GI Pathology
- Type
- article
- Field-Weighted Citation Impact
- 0.00