Axial Compression Behavior of L-Shaped CFST Columns Enhanced by Fully Bolted Threaded-Rod Confinement: An Experimental Assessment

Special-shaped concrete-filled steel tube (CFST) columns are increasingly adopted as efficient vertical load-carrying members in integrated residential structural systems. However, their intrinsically nonuniform confinement promotes early local buckling and bulging of tube plates and limits deformation stability under axial compression. This study presents an experimental assessment of an L-shaped CFST column enhanced by a fully bolted threaded-rod transverse tie (RT) system, which is intended to strengthen confinement delivery and delay tube instability. Two 1500 mm-high specimens with identical cross-sectional dimensions (400 mm × 200 mm legs; 6 mm wall thickness) were fabricated using Q235 steel and C30 concrete: one conventional baseline (L1) and one RT-improved column (L2) with pre-drilled bolt holes at 150 mm spacing and installed threaded rods (10 mm nominal diameter) to provide a distributed transverse restraint. Monotonic axial compression tests were conducted under staged load control while recording the axial shortening, mid-height lateral deflection, and longitudinal and transverse steel strains. The RT detailing postponed the onset of visible local buckling, tightened the lateral deflection envelope, and increased the measured peak axial resistance from 4354 kN (L1) to 5354 kN (L2), corresponding to an increase of approximately 23%. The combined deformation and strain evidence indicates that the RT system improves the confinement effectiveness by stabilizing the tube dilation and promoting a more controlled instability evolution. Overall, the fully bolted RT approach offers a practical and fabrication-compatible pathway for enhancing the axial strength and deformation performance of L-shaped CFST columns.

Authors

Institutions

Publication Details

Journal
Journal of Composites Science
Published
2026-02-02
DOI
https://doi.org/10.3390/jcs10020077
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial Compression Behavior of L-Shaped CFST Columns Enhanced by Fully Bolted Threaded-Rod Confinement: An Experimental Assessment

Weiyuan Fang, Abdul Ghafar Wahab, Zhong Tao
Journal of Composites Science
Structural Load-Bearing Analysis
article

Axial Compression Behavior of L-Shaped CFST Columns Enhanced by Fully Bolted Threaded-Rod Confinement: An Experimental Assessment

Weiyuan Fang, Abdul Ghafar Wahab, Zhong Tao
article en

Abstract

Special-shaped concrete-filled steel tube (CFST) columns are increasingly adopted as efficient vertical load-carrying members in integrated residential structural systems. However, their intrinsically nonuniform confinement promotes early local buckling and bulging of tube plates and limits deformation stability under axial compression. This study presents an experimental assessment of an L-shaped CFST column enhanced by a fully bolted threaded-rod transverse tie (RT) system, which is intended to strengthen confinement delivery and delay tube instability. Two 1500 mm-high specimens with identical cross-sectional dimensions (400 mm × 200 mm legs; 6 mm wall thickness) were fabricated using Q235 steel and C30 concrete: one conventional baseline (L1) and one RT-improved column (L2) with pre-drilled bolt holes at 150 mm spacing and installed threaded rods (10 mm nominal diameter) to provide a distributed transverse restraint. Monotonic axial compression tests were conducted under staged load control while recording the axial shortening, mid-height lateral deflection, and longitudinal and transverse steel strains. The RT detailing postponed the onset of visible local buckling, tightened the lateral deflection envelope, and increased the measured peak axial resistance from 4354 kN (L1) to 5354 kN (L2), corresponding to an increase of approximately 23%. The combined deformation and strain evidence indicates that the RT system improves the confinement effectiveness by stabilizing the tube dilation and promoting a more controlled instability evolution. Overall, the fully bolted RT approach offers a practical and fabrication-compatible pathway for enhancing the axial strength and deformation performance of L-shaped CFST columns.

Journal of Composites ScienceVol. 10(2)
Kunming University of Science and Technology (CN), CCCC Highway Consultants (China) (CN), Kunming Metallurgy College (CN)
Sustainable cities and communities
Openalex Percentile: Top 70%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.