Flexible radiochromic films based on 10.12-pentacosadiynoic acid-doped ionogel enabling 2D real time dosimetry

In this work, we report the development and characterization of a new flexible radiochromic film based on 10.12-pentacosadiynoic acid (10.12-PCDA) embedded in an ionogel (IG) matrix. Designed for real-time, in-situ 2D dosimetry, the film integrates all components within a single, flexible layer. This enhances its adaptability to curved and irregular surfaces and facilitates adjustment to patient morphology. The ionogels were produced by immobilizing the ionic liquid 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (BMIM TFSI) within a polymeric matrix of Poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-co-HFP), achieving thin (100 μm) and flexible (Young’s modulus of 4 MPa) films. Ionogels were doped with the radiochromic molecule 10.12-PCDA, achieving a maximum concentration of 8.2 wt.% in the film, which confers it with high sensitivity to radiation. Dose response calibration was performed with a 90 kV microfocus X-ray source and revealed a strong correlation between changes in the optical density of the films irradiated and radiation dose, with the most sensitive formulation (8.2 wt.% 10.12-PCDA, IL/polymer ratio 3:1) displaying a detection limit of 0.25 Gy. The radiochromic properties of these films, combined with a customised opto-mechanical setup and open-source colour analysis software, enable a system for 2D and real-time dosimetry with a spatial resolution of 1 mm. The films demonstrated excellent flexibility, mechanical stability post-irradiation, and reliable dose distribution assessment on curved surfaces (90 to 180° curvature angle). These results position 10.12-PCDA@IG films as promising candidates for in vivo dosimetry on the patient skin. • Development of flexible sensors based on 10.12-PCDA ionogels combined with an easy optical readout for colorimetric radiation detection. • Integration into a thin, flexible ionogel, suitable for curved surfaces and wearables. • Linear response at doses of 0.25–10 Gy with spatial resolution of 1 mm. • Possibility of real-time monitoring through simple and cheap optical analysis.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2026-02-02
DOI
https://doi.org/10.1016/j.radmeas.2026.107628
Primary Topic
Nanoplatforms for cancer theranostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible radiochromic films based on 10.12-pentacosadiynoic acid-doped ionogel enabling 2D real time dosimetry

Xavier Muñoz‐Berbel, Silvia Mena, Gonzalo Guirado, Naseer Ahmad et al.
Radiation Measurements
Nanoplatforms for cancer theranostics
article

Flexible radiochromic films based on 10.12-pentacosadiynoic acid-doped ionogel enabling 2D real time dosimetry

Xavier Muñoz‐Berbel, Silvia Mena, Gonzalo Guirado, Naseer Ahmad, Mar Álvarez, Consuelo Guardiola
article en

Abstract

In this work, we report the development and characterization of a new flexible radiochromic film based on 10.12-pentacosadiynoic acid (10.12-PCDA) embedded in an ionogel (IG) matrix. Designed for real-time, in-situ 2D dosimetry, the film integrates all components within a single, flexible layer. This enhances its adaptability to curved and irregular surfaces and facilitates adjustment to patient morphology. The ionogels were produced by immobilizing the ionic liquid 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (BMIM TFSI) within a polymeric matrix of Poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-co-HFP), achieving thin (100 μm) and flexible (Young’s modulus of 4 MPa) films. Ionogels were doped with the radiochromic molecule 10.12-PCDA, achieving a maximum concentration of 8.2 wt.% in the film, which confers it with high sensitivity to radiation. Dose response calibration was performed with a 90 kV microfocus X-ray source and revealed a strong correlation between changes in the optical density of the films irradiated and radiation dose, with the most sensitive formulation (8.2 wt.% 10.12-PCDA, IL/polymer ratio 3:1) displaying a detection limit of 0.25 Gy. The radiochromic properties of these films, combined with a customised opto-mechanical setup and open-source colour analysis software, enable a system for 2D and real-time dosimetry with a spatial resolution of 1 mm. The films demonstrated excellent flexibility, mechanical stability post-irradiation, and reliable dose distribution assessment on curved surfaces (90 to 180° curvature angle). These results position 10.12-PCDA@IG films as promising candidates for in vivo dosimetry on the patient skin. • Development of flexible sensors based on 10.12-PCDA ionogels combined with an easy optical readout for colorimetric radiation detection. • Integration into a thin, flexible ionogel, suitable for curved surfaces and wearables. • Linear response at doses of 0.25–10 Gy with spatial resolution of 1 mm. • Possibility of real-time monitoring through simple and cheap optical analysis.

Radiation MeasurementsVol. 192
Universitat Autònoma de Barcelona (ES), Instituto de Salud Carlos III (ES), Institut de Microelectrònica de Barcelona (ES)
Openalex Percentile: Top 70%
Nanoplatforms for cancer theranostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.