Challenges in measuring low concentration of overlapping elements with EDS and the need for verification with secondary standard composition

Quantitative analysis using energy-dispersive spectrometry (EDS) has been shown to achieve high accuracy equivalent to that of wavelength-dispersive x-ray spectrometry (WDS) even in the case of highly overlapped X-ray peaks of major elements and high precision in the case of trace elements with concentrations below 1 wt.%. With reliable pulse pile-up correction, accurate, unnormalized EDS quantification was also demonstrated at count rates above 200 kcps. This work studies the EDS quantification of samples exhibiting these three analytical challenges simultaneously: quantification of trace elements (< 1 wt%), overlapping X-ray peaks of major elements (small peak on large peak), and high-count rates (to improve productivity of these measurements). A secondary standard was used to optimise and validate the collection conditions for the measurement of an unknown slag sample exhibiting a heterogeneous microstructure containing trace level of Mn. Accurate quantification down to 0.1 wt% and mapping of segregation in the order of 0.2wt% were possible with modern EDS technology.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-01-29
DOI
https://doi.org/10.1051/epjconf/202634901016/pdf
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges in measuring low concentration of overlapping elements with EDS and the need for verification with secondary standard composition

P. Pinard, Simon Burgess, Lucia Spasevski, John Qing Zhang
Springer Link (Chiba Institute of Technology)
X-ray Spectroscopy and Fluorescence Analysis
article

Challenges in measuring low concentration of overlapping elements with EDS and the need for verification with secondary standard composition

P. Pinard, Simon Burgess, Lucia Spasevski, John Qing Zhang
article en

Abstract

Quantitative analysis using energy-dispersive spectrometry (EDS) has been shown to achieve high accuracy equivalent to that of wavelength-dispersive x-ray spectrometry (WDS) even in the case of highly overlapped X-ray peaks of major elements and high precision in the case of trace elements with concentrations below 1 wt.%. With reliable pulse pile-up correction, accurate, unnormalized EDS quantification was also demonstrated at count rates above 200 kcps. This work studies the EDS quantification of samples exhibiting these three analytical challenges simultaneously: quantification of trace elements (< 1 wt%), overlapping X-ray peaks of major elements (small peak on large peak), and high-count rates (to improve productivity of these measurements). A secondary standard was used to optimise and validate the collection conditions for the measurement of an unknown slag sample exhibiting a heterogeneous microstructure containing trace level of Mn. Accurate quantification down to 0.1 wt% and mapping of segregation in the order of 0.2wt% were possible with modern EDS technology.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 70%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.