Point-of-Care Bilirubin Testing in Neonates: Comparative Performance of Blood Gas Analysis and Transcutaneous Bilirubinometry
<b>Background</b>: Neonatal jaundice is a common condition with potentially severe complications such as bilirubin-induced neurological dysfunction and kernicterus. While serum bilirubin (SBR) remains the standard laboratory measurement, point-of-care methods, such as transcutaneous bilirubinometry (TcB) and blood gas analysers (BGAs), offer rapid, less invasive alternatives. Direct comparisons of their diagnostic accuracy remain limited. <b>Objective</b>: The aim of this study was to assess and compare diagnostic accuracy and clinical utility of TcB and BGA against SBR in neonatal hyperbilirubinaemia screening. <b>Methods</b>: This retrospective study included neonates (n = 221) with concurrent SBR, BGA, and TcB measurements (n = 333). Assessment was via Passing-Bablok regression, Bland-Altman analysis, and Spearman correlation. Diagnostic performance was evaluated against jaundice thresholds in phototherapy charts (≥95th percentile threshold). Subgroup analyses considered phototherapy status, haemoglobin concentration, and Fitzpatrick skin type. <b>Results</b>: BGA showed stronger agreement with SBR (R<sup>2</sup> = 0.88) than TcB (R<sup>2</sup> = 0.43). BGA remained accurate regardless of phototherapy or haemoglobin levels. TcB accuracy declined post-phototherapy with reduced predictive value in darker-skinned neonates (Fitzpatrick III-VI) and increased false discovery rates. Both methods demonstrated low sensitivity (45.8%) but high specificity (>95%) and negative predictive value (~91%) for clinically significant hyperbilirubinaemia. BGA had a higher diagnostic odds ratio (47.5) than TcB (19.3). When individual patient sequential SBR and BGA measurements were compared for jaundice tracking (n = 175), there was high correlation, (r = 0.971) with no statistical differences, and 50% of measurements achieving agreement within 10 μmol/L. <b>Conclusions</b>: BGA is a more reliable alternative to SBR than TcB, particularly in time-critical or resource-limited settings. While TcB remains a non-invasive screening tool, limited accuracy post-phototherapy and with darker skinned neonates indicate confirmatory SBR testing. These findings support the selective and context-aware use of BGA and TcB to optimise neonatal hyperbilirubinaemia management and reduce interventions.
Authors
- Wei Fan (ORCID: https://orcid.org/0000-0002-0616-4538)
- Bincy Francis (ORCID: https://orcid.org/0009-0007-0448-7206)
- David Tran
- Kay Weng Choy (ORCID: https://orcid.org/0000-0001-8669-7352)
- Amy Surkitt
- Rami Subhi
- George Francis Dargaville
- Andrew Xu
Institutions
- The University of Melbourne (AU)
- Northern Health (AU)
- Melbourne Health (AU)
Publication Details
- Journal
- Healthcare
- Published
- 2026-02-01
- DOI
- https://doi.org/10.3390/healthcare14030370
- Primary Topic
- Neonatal Health and Biochemistry
- Type
- article
- Field-Weighted Citation Impact
- 0.00