Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry

The increasing interest of the optics manufacturing industry in apshere and freeform optics leads to a high demand in accurate form measurement of such surfaces. The tilted-wave interferometer offers a fast and flexible solution to the needs. However, similar to other interferometric methods, ambiguities between specimen misalignment and certain form errors exist. To ensure the accuracy of the form measurement, the accuracy of the specimen positioning is crucial. This work presents a multi-step specimen positioning procedure that uses the Cat’s Eye reference position as a fixed reference position. Different alignment criteria are evaluated by simulation and implemented into an alignment algorithm for specimen alignment into the Cat’s Eye position. The procedure, investigated with multiple test specimens, shows a good short-term repeatability with a standard deviation below 30 nm. The use of this specimen alignment procedure will significantly reduce surface form measurement errors associated with axial misalignment and improve the overall measurement accuracy of the tilted-wave interferometer.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-29
DOI
https://doi.org/10.1051/jeos/2025016/pdf
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry

Gregor Scholz, Ines Fortmeier, D. Evers
Springer Link (Chiba Institute of Technology)
Optical measurement and interference techniques
article

Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry

Gregor Scholz, Ines Fortmeier, D. Evers
article en

Abstract

The increasing interest of the optics manufacturing industry in apshere and freeform optics leads to a high demand in accurate form measurement of such surfaces. The tilted-wave interferometer offers a fast and flexible solution to the needs. However, similar to other interferometric methods, ambiguities between specimen misalignment and certain form errors exist. To ensure the accuracy of the form measurement, the accuracy of the specimen positioning is crucial. This work presents a multi-step specimen positioning procedure that uses the Cat’s Eye reference position as a fixed reference position. Different alignment criteria are evaluated by simulation and implemented into an alignment algorithm for specimen alignment into the Cat’s Eye position. The procedure, investigated with multiple test specimens, shows a good short-term repeatability with a standard deviation below 30 nm. The use of this specimen alignment procedure will significantly reduce surface form measurement errors associated with axial misalignment and improve the overall measurement accuracy of the tilted-wave interferometer.

Springer Link (Chiba Institute of Technology)
Industry, innovation and infrastructure
Openalex Percentile: Top 29%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of the positioning accuracy of the Cat’s Eye as a reference position in asphere-measuring interferometry — Gregor Scholz, Ines Fortmeier, et al. · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS