Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization

The magnetic gradient tensor measurement system (MGTMS) is critical for detecting and localizing ferromagnetic targets. However, its localization accuracy is closely linked to measurement precision, which is often compromised by sensor misalignment errors. To mitigate these errors, this study proposes a practical calibration method using a standard magnetic source, achieving effective misalignment correction with minimal system alteration. The proposed method is validated through both simulations and localization experiments. Simulation results indicate that the root mean square error (RMSE) of the calibrated tensor values is reduced by three orders of magnitude compared to the uncalibrated state. Experimental results further demonstrate that the average localization error decreases from 0.040 m to 0.019 m after calibration, corresponding to a 52.5% improvement in positioning accuracy. These results highlight the potential of improving the accuracy of MGTMS-based target localization in practical applications.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-10-01
DOI
https://doi.org/10.1051/matecconf/202541301009/pdf
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization

Yingzi Zhang, Qingping Yang, Yali Shen
Springer Link (Chiba Institute of Technology)
Geophysical and Geoelectrical Methods
article

Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization

Yingzi Zhang, Qingping Yang, Yali Shen
article en

Abstract

The magnetic gradient tensor measurement system (MGTMS) is critical for detecting and localizing ferromagnetic targets. However, its localization accuracy is closely linked to measurement precision, which is often compromised by sensor misalignment errors. To mitigate these errors, this study proposes a practical calibration method using a standard magnetic source, achieving effective misalignment correction with minimal system alteration. The proposed method is validated through both simulations and localization experiments. Simulation results indicate that the root mean square error (RMSE) of the calibrated tensor values is reduced by three orders of magnitude compared to the uncalibrated state. Experimental results further demonstrate that the average localization error decreases from 0.040 m to 0.019 m after calibration, corresponding to a 52.5% improvement in positioning accuracy. These results highlight the potential of improving the accuracy of MGTMS-based target localization in practical applications.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 25%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Correction of misalignment errors in the magnetic gradient tensor measurement system and its application in localization — Yingzi Zhang, Qingping Yang, et al. · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS