Occupational and ambient radiation dose monitoring in a nuclear medicine department

Monitoring radiation doses is critical for safety in nuclear medicine (NM) departments. This study assessed personal and ambient radiation doses during routine NM procedures and compliance with International Commission on Radiological Protection (ICRP) limits at the new NM department of Abu Ali Sina Hospital, Shiraz, Iran. Between March and April 2024, 500 procedures involving 99mTc and 131I were performed. Personal dose equivalents Hp(10), Hp(3), and Hp(0.07) were measured for staff using calibrated TLD-100 dosemeters. Ambient doses were monitored across the department. Measured doses included 11.19 mSv (fingers), 14.62 mSv (hands), 0.11 mSv (whole body), and 0.03 mSv (eye lens), with Technologist 2 showing the highest hand dose. Ambient monitoring showed the highest dose rate (1.19 μSv/h) in the waiting area near the hot lab, mainly from post-injection patients. While all doses remained within ICRP limits, the findings indicate the need for improved shielding and optimized workflow to minimize extremity and environmental exposure.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-12-30
DOI
https://doi.org/10.1093/rpd/ncaf196
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occupational and ambient radiation dose monitoring in a nuclear medicine department

S. Sina, Mohammad Hossein Sadeghi, Mohaddeseh Heydarinia, Fatemeh Norouz Alizadeh et al.
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Occupational and ambient radiation dose monitoring in a nuclear medicine department

S. Sina, Mohammad Hossein Sadeghi, Mohaddeseh Heydarinia, Fatemeh Norouz Alizadeh, Mahboobeh Sheikhi
article en

Abstract

Monitoring radiation doses is critical for safety in nuclear medicine (NM) departments. This study assessed personal and ambient radiation doses during routine NM procedures and compliance with International Commission on Radiological Protection (ICRP) limits at the new NM department of Abu Ali Sina Hospital, Shiraz, Iran. Between March and April 2024, 500 procedures involving 99mTc and 131I were performed. Personal dose equivalents Hp(10), Hp(3), and Hp(0.07) were measured for staff using calibrated TLD-100 dosemeters. Ambient doses were monitored across the department. Measured doses included 11.19 mSv (fingers), 14.62 mSv (hands), 0.11 mSv (whole body), and 0.03 mSv (eye lens), with Technologist 2 showing the highest hand dose. Ambient monitoring showed the highest dose rate (1.19 μSv/h) in the waiting area near the hot lab, mainly from post-injection patients. While all doses remained within ICRP limits, the findings indicate the need for improved shielding and optimized workflow to minimize extremity and environmental exposure.

Radiation Protection Dosimetry
Shiraz University (IR), Shiraz University of Medical Sciences (IR)
Openalex Percentile: Top 27%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Occupational and ambient radiation dose monitoring in a nuclear medicine department — S. Sina, Mohammad Hossein Sadeghi, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS