Reconstruction of weak pulse signals based on 3D DSM Fabry-Perot cavity stochastic resonance

In this paper, two stochastic resonance systems for reconstructing noise-containing pulse signals are designed based on Fabry-Perot cavity with 3D DSM. The effects of different parameters in two stochastic resonance systems on bistability are analysed, the cross-correlation coefficient and cross-correlation gain between the original input signal, the input signal, and the output signal are calculated as a means of evaluating their signal reconstruction performance. The results show that their maximum cross-correlation gains reach 3.2 and 3, respectively, both stochastic resonance systems can effectively reconstruct noisy pulse signals. By comparing the simulation data of the two systems, it is known that the stochastic resonance system using photonic crystals can effectively reduce the need for pulse signal strength and noise intensity. This study provides an effective means of detecting weak pulse signals.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-08-11
DOI
https://doi.org/10.1051/jnwpu/20254330546/pdf
Primary Topic
stochastic dynamics and bifurcation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconstruction of weak pulse signals based on 3D DSM Fabry-Perot cavity stochastic resonance

Springer Link (Chiba Institute of Technology)
stochastic dynamics and bifurcation
article

Reconstruction of weak pulse signals based on 3D DSM Fabry-Perot cavity stochastic resonance

article en

Abstract

In this paper, two stochastic resonance systems for reconstructing noise-containing pulse signals are designed based on Fabry-Perot cavity with 3D DSM. The effects of different parameters in two stochastic resonance systems on bistability are analysed, the cross-correlation coefficient and cross-correlation gain between the original input signal, the input signal, and the output signal are calculated as a means of evaluating their signal reconstruction performance. The results show that their maximum cross-correlation gains reach 3.2 and 3, respectively, both stochastic resonance systems can effectively reconstruct noisy pulse signals. By comparing the simulation data of the two systems, it is known that the stochastic resonance system using photonic crystals can effectively reduce the need for pulse signal strength and noise intensity. This study provides an effective means of detecting weak pulse signals.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 26%
stochastic dynamics and bifurcation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.