Measurement of insertion loss and gain in variable hear-through and noise cancellation modes of true wireless earbuds

This paper presents the results of objective tests to assess the insertion loss and gain performance of three true wireless earbuds that featured both active noise cancellation (ANC) and hear-through functionality. An acoustic test fixture (ATF) was used to examine the earbuds’ attenuation and boosting of broadband noise, linearity of performance for different presentation levels, and consistency of performance over time. The results show that devices are capable of a wide range of both attenuation and boosting, with hear-through modes providing significant levels of boosting in frequencies that are considered important to the intelligibility of speech. Furthermore, none of the hear-through modes tested were found to provide responses that suggested the devices were capable of providing full acoustic transparency. The results may also be useful for those seeking to produce models that replicate key aspects of insertion loss and gain performance in contemporary true wireless earbuds.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-04-15
DOI
https://doi.org/10.1051/aacus/2025013/pdf
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of insertion loss and gain in variable hear-through and noise cancellation modes of true wireless earbuds

Alan Archer-Boyd, Damian T. Murphy, Jay Harrison
Springer Link (Chiba Institute of Technology)
Hearing Loss and Rehabilitation
article

Measurement of insertion loss and gain in variable hear-through and noise cancellation modes of true wireless earbuds

Alan Archer-Boyd, Damian T. Murphy, Jay Harrison
article en

Abstract

This paper presents the results of objective tests to assess the insertion loss and gain performance of three true wireless earbuds that featured both active noise cancellation (ANC) and hear-through functionality. An acoustic test fixture (ATF) was used to examine the earbuds’ attenuation and boosting of broadband noise, linearity of performance for different presentation levels, and consistency of performance over time. The results show that devices are capable of a wide range of both attenuation and boosting, with hear-through modes providing significant levels of boosting in frequencies that are considered important to the intelligibility of speech. Furthermore, none of the hear-through modes tested were found to provide responses that suggested the devices were capable of providing full acoustic transparency. The results may also be useful for those seeking to produce models that replicate key aspects of insertion loss and gain performance in contemporary true wireless earbuds.

Springer Link (Chiba Institute of Technology)
Openalex Percentile: Top 27%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.