Medical image upsampling algorithm to reduce errors in grid-based ultrasound simulation
Clinical imaging resolution is often insufficient for accurate ultrasound simulation in personalised treatment planning. Naive image upsampling algorithms introduce artifacts that reduce simulation accuracy. We develop a Gaussian smoothing and mesh-based upsampling method and evaluate upsampled image fidelity and ultrasound simulation accuracy using an ex vivo high resolution human cervical vertebra volume obtained with hierarchical phase-contrast tomography, against linear and nearest neighbour interpolation. The mesh-based method significantly and consistently reduced L2 and L∞ errors and reduced focal errors with inconsistent significance. Medical image upsampling for ultrasound simulation should be completed with edge-aware methods to improve accuracy.
Authors
- Rui Xu (ORCID: https://orcid.org/0000-0003-1606-0932)
- Donny Liangpu Liu
Institutions
- University College London (GB)
- Imperial College London (GB)
Publication Details
- Journal
- JASA Express Letters
- Published
- 2026-02-01
- DOI
- https://doi.org/10.1121/10.0042350
- Primary Topic
- Ultrasound Imaging and Elastography
- Type
- article
- Field-Weighted Citation Impact
- 0.00