Temperature distributions in MEMS microheaters during gas phase experiments in an environmental TEM

Reliable sample temperature measurements are essential in environmental transmission electron microscope (ETEM) experiments. In this study, the effect of flowing gases on the temperature distribution at a MEMS microheater in gas phase is investigated. A computational fluid dynamics model is developed and compared with experimental data. The modeling results agree well with experimental measurements based on the melting temperature of Zn nanoparticles, confirming the model's reliability. The results show that the temperature profile across the heating chip in the case with H<sub>2</sub> environment is less uniform compared to the case of vacuum and O<sub>2</sub>. For example, at a set temperature of 900 °C in 3 mbar H<sub>2</sub>, a temperature difference of 60 °C is observed between the central sample position compared to the surrounding arc-shaped heater which also is the temperature sensor, while the difference in the vacuum case is only 13 °C. Temperature is one of the key parameters in in-situ TEM experiments and, therefore, these findings are important in the design of ETEM experiments, especially when using MEMS microheaters with relatively large distances between TEM sample and microheater/sensor.

Authors

Institutions

Publication Details

Journal
Ultramicroscopy
Published
2026-02-01
DOI
https://doi.org/10.1016/j.ultramic.2026.114326
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature distributions in MEMS microheaters during gas phase experiments in an environmental TEM

Magnus Björnsson, Zhongtao Ma, Julian Taubmann, Joerg R. Jinschek et al.
Ultramicroscopy
Advanced Electron Microscopy Techniques and Applications
article

Temperature distributions in MEMS microheaters during gas phase experiments in an environmental TEM

Magnus Björnsson, Zhongtao Ma, Julian Taubmann, Joerg R. Jinschek, Arash Nemati, Søren Bredmose Simonsen, Amit Kumar, Kristian Speranza Mølhave
article en

Abstract

Reliable sample temperature measurements are essential in environmental transmission electron microscope (ETEM) experiments. In this study, the effect of flowing gases on the temperature distribution at a MEMS microheater in gas phase is investigated. A computational fluid dynamics model is developed and compared with experimental data. The modeling results agree well with experimental measurements based on the melting temperature of Zn nanoparticles, confirming the model's reliability. The results show that the temperature profile across the heating chip in the case with H<sub>2</sub> environment is less uniform compared to the case of vacuum and O<sub>2</sub>. For example, at a set temperature of 900 °C in 3 mbar H<sub>2</sub>, a temperature difference of 60 °C is observed between the central sample position compared to the surrounding arc-shaped heater which also is the temperature sensor, while the difference in the vacuum case is only 13 °C. Temperature is one of the key parameters in in-situ TEM experiments and, therefore, these findings are important in the design of ETEM experiments, especially when using MEMS microheaters with relatively large distances between TEM sample and microheater/sensor.

UltramicroscopyVol. 282
Technical University of Denmark (DK)
Openalex Percentile: Top 76%
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.