Remote prediction of cardiorespiratory fitness in a preoperative cohort: exploring short and long-term heart rate variability

Abstract Background Wearable sensors offer a scalable alternative to cardiopulmonary exercise testing for assessing cardiorespiratory fitness, and there is growing evidence to support their use for remote VO 2 max estimation. This study investigated whether heart rate variability (HRV) measures derived from wearable ECG sensors improve VO 2 max estimations in a preoperative cohort and compared the relative contributions of short- and long-term HRV features. ECG and accelerometer data from 198 participants scheduled for major abdominal surgery (REMOTES study, ClinicalTrials.gov: ID NCT06042023) were collected over 72 h. Measures including physical activity, steps, heart rate, and HRV were extracted. Short-term (5-minutes) and long-term (24-hour) heart rate variability features were extracted from free-living ECG data. Two LASSO regression models with five-fold cross-validation were developed: a baseline model (excluding HRV) and a HRV model. Results After exclusions, 163 participants were included in analyses. The HRV model outperformed the baseline across all metrics, achieving a higher R 2 (0.47 ± 0.12 vs. 0.42 ± 0.13) and lower mean absolute error (2.63 ± 0.34 vs. 2.77 ± 0.38 ml/kg/min), root mean square error (3.38 ± 0.53 vs. 3.54 ± 0.57 ml/kg/min) and absolute percentage error (15.55 ± 2.19% vs. 16.22 ± 2.45%). Analysis of feature contributions identified long-term HRV (SDANN HR 24), age, gender, and step-counts as key contributors to model performance. Conclusion HRV features from wearable data, especially long-term measures, can improve remote VO 2 max predictions in a clinical cohort. While performance gains were small, these findings support the integration of HRV features into remote monitoring systems in real-world settings. Long-term HRV measures derived from heart rate signals offer a practical option for cardiorespiratory fitness assessment, requiring minimal additional processing. Trail registration This study was registered at ClinicalTrials.gov (Clinical trial number: NCT06042023) and was registered retrospectively on 11/09/2023.

Authors

Institutions

Publication Details

Journal
BMC Digital Health
Published
2026-02-01
DOI
https://doi.org/10.1186/s44247-026-00239-y
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remote prediction of cardiorespiratory fitness in a preoperative cohort: exploring short and long-term heart rate variability

Alexios Dosis, David Jayne, Aron B. Syversen, Zhiqiang Zhang et al.
BMC Digital Health
Heart Rate Variability and Autonomic Control
article

Remote prediction of cardiorespiratory fitness in a preoperative cohort: exploring short and long-term heart rate variability

Alexios Dosis, David Jayne, Aron B. Syversen, Zhiqiang Zhang, David Wong
article en

Abstract

Abstract Background Wearable sensors offer a scalable alternative to cardiopulmonary exercise testing for assessing cardiorespiratory fitness, and there is growing evidence to support their use for remote VO 2 max estimation. This study investigated whether heart rate variability (HRV) measures derived from wearable ECG sensors improve VO 2 max estimations in a preoperative cohort and compared the relative contributions of short- and long-term HRV features. ECG and accelerometer data from 198 participants scheduled for major abdominal surgery (REMOTES study, ClinicalTrials.gov: ID NCT06042023) were collected over 72 h. Measures including physical activity, steps, heart rate, and HRV were extracted. Short-term (5-minutes) and long-term (24-hour) heart rate variability features were extracted from free-living ECG data. Two LASSO regression models with five-fold cross-validation were developed: a baseline model (excluding HRV) and a HRV model. Results After exclusions, 163 participants were included in analyses. The HRV model outperformed the baseline across all metrics, achieving a higher R 2 (0.47 ± 0.12 vs. 0.42 ± 0.13) and lower mean absolute error (2.63 ± 0.34 vs. 2.77 ± 0.38 ml/kg/min), root mean square error (3.38 ± 0.53 vs. 3.54 ± 0.57 ml/kg/min) and absolute percentage error (15.55 ± 2.19% vs. 16.22 ± 2.45%). Analysis of feature contributions identified long-term HRV (SDANN HR 24), age, gender, and step-counts as key contributors to model performance. Conclusion HRV features from wearable data, especially long-term measures, can improve remote VO 2 max predictions in a clinical cohort. While performance gains were small, these findings support the integration of HRV features into remote monitoring systems in real-world settings. Long-term HRV measures derived from heart rate signals offer a practical option for cardiorespiratory fitness assessment, requiring minimal additional processing. Trail registration This study was registered at ClinicalTrials.gov (Clinical trial number: NCT06042023) and was registered retrospectively on 11/09/2023.

BMC Digital HealthVol. 4(1)
University of Leeds (GB)
Bowel Cancer UK, National Institute for Health and Care Research, Engineering and Physical Sciences Research Council
Reduced inequalities
Openalex Percentile: Top 70%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.