Multiplexed potentiometric sensing of nitrite in environmental waters

Nitrite is a key water quality indicator whose monitoring is essential for environmental and human safety protection, yet conventional methods such as chromatography and spectrophotometry require expensive instrumentation and centralised laboratory infrastructure. Potentiometric solid-contact ion-selective electrodes, particularly in screen-printed formats, offer a promising cost-effective and miniaturised alternative, but their use in real scenarios still demands versatile operation modes and affordable multiplexed readout to increase throughput and statistical robustness. In this context, a potentiometric nitrite sensor based on commercial screen-printed electrodes (SPEs) modified with graphene oxide and functionalised with an optimised polymeric membrane containing Nitrite Ionophore VI, was developed and characterised for batch, drop, and flow analysis using a custom open-source multiplexer that extends a single-channel EmStat4M potentiostat (PalmSens BV) to eight pseudo-parallel channels. The NO<sub>2</sub>-SPEs exhibited a Nernstian response over the linear range from 3.0 × 10<sup>-6</sup> to 1.0 × 10<sup>-2</sup> M under batch, drop, and flow analytical modes, covering nitrite's regulated contaminant level in freshwater. The potentiometric response was additionally characterised by a fast response time (<40 s), good reversibility, reproducibility (RSD <4.3% for slope between identical sensor units, n = 16), and potential stability (medium-term drift of 32.8 ± 15.3 μV min<sup>-1</sup>) under batch mode. The proposed potentiometric systems were applied to nitrite determination in spiked river and groundwater samples, yielding recovery values from 83.5 to 108.9% across all three operational modes. Beyond these analytical figures of merit, the combined sensor-multiplexer platform provides a practical route toward decentralised measurements, enabling sensing automation, increased statistical sample size, and multianalyte detection capabilities.

Authors

Institutions

Publication Details

Journal
Analytica Chimica Acta
Published
2026-02-01
DOI
https://doi.org/10.1016/j.aca.2026.345190
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiplexed potentiometric sensing of nitrite in environmental waters

Begoña Espiña, Raquel B. Queirós, Marília Barreiros dos Santos, Renato L. Gil et al.
Analytica Chimica Acta
Analytical Chemistry and Sensors
article

Multiplexed potentiometric sensing of nitrite in environmental waters

Begoña Espiña, Raquel B. Queirós, Marília Barreiros dos Santos, Renato L. Gil, Álvaro Geraldes, Samuel Silva
article en

Abstract

Nitrite is a key water quality indicator whose monitoring is essential for environmental and human safety protection, yet conventional methods such as chromatography and spectrophotometry require expensive instrumentation and centralised laboratory infrastructure. Potentiometric solid-contact ion-selective electrodes, particularly in screen-printed formats, offer a promising cost-effective and miniaturised alternative, but their use in real scenarios still demands versatile operation modes and affordable multiplexed readout to increase throughput and statistical robustness. In this context, a potentiometric nitrite sensor based on commercial screen-printed electrodes (SPEs) modified with graphene oxide and functionalised with an optimised polymeric membrane containing Nitrite Ionophore VI, was developed and characterised for batch, drop, and flow analysis using a custom open-source multiplexer that extends a single-channel EmStat4M potentiostat (PalmSens BV) to eight pseudo-parallel channels. The NO<sub>2</sub>-SPEs exhibited a Nernstian response over the linear range from 3.0 × 10<sup>-6</sup> to 1.0 × 10<sup>-2</sup> M under batch, drop, and flow analytical modes, covering nitrite's regulated contaminant level in freshwater. The potentiometric response was additionally characterised by a fast response time (<40 s), good reversibility, reproducibility (RSD <4.3% for slope between identical sensor units, n = 16), and potential stability (medium-term drift of 32.8 ± 15.3 μV min<sup>-1</sup>) under batch mode. The proposed potentiometric systems were applied to nitrite determination in spiked river and groundwater samples, yielding recovery values from 83.5 to 108.9% across all three operational modes. Beyond these analytical figures of merit, the combined sensor-multiplexer platform provides a practical route toward decentralised measurements, enabling sensing automation, increased statistical sample size, and multianalyte detection capabilities.

Analytica Chimica ActaVol. 1392
International Iberian Nanotechnology Laboratory (PT)
Industry, innovation and infrastructure
Openalex Percentile: Top 71%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.