BanglaOCT2025: A Population-Specific Fovea-Centric OCT Dataset with Self-Supervised Volumetric Restoration Using Flip-Flop Swin Transformers

<b>Background:</b> Age-related macular degeneration (AMD) is a major cause of vision loss, yet publicly available Optical Coherence Tomography (OCT) datasets lack demographic diversity, particularly from South Asian populations. Existing datasets largely represent Western cohorts, limiting AI generalizability. Moreover, raw OCT volumes contain redundant spatial information and speckle noise, hindering efficient analysis. <b>Methods:</b> We introduce BanglaOCT2025, a retrospective dataset collected from the National Institute of Ophthalmology and Hospital (NIOH), Bangladesh, using Nidek RS-330 Duo 2 and RS-3000 Advance systems. We propose a novel preprocessing pipeline comprising two stages: (1) A constraint-based centroid minimization algorithm automatically localizes the foveal center and extracts a fixed 33-slice macular sub-volume, robust to retinal tilt and acquisition variability; and (2) A self-supervised volumetric denoising module based on a Flip-Flop Swin Transformer (FFSwin) backbone suppresses speckle noise without requiring paired clean reference data. <b>Results:</b> The dataset comprises 1585 OCT volumes (202,880 B-scans), including 857 expert-annotated cases (54 DryAMD, 61 WetAMD, and 742 NonAMD). Denoising quality was evaluated using reference-free volumetric metrics, paired statistical analysis, and blinded clinical review by a retinal specialist, confirming preservation of pathological biomarkers and absence of hallucination. Under a controlled paired evaluation using the same classifier with frozen weights, downstream AMD classification accuracy improved from 69.08% to 99.88%, interpreted as an upper-bound estimate of diagnostic signal recoverability rather than independent generalization. <b>Conclusions:</b> BanglaOCT2025 is the first clinically validated OCT dataset representing the Bengali population and establishes a reproducible fovea-centric volumetric preprocessing and restoration framework for AMD analysis, with future validation across independent and multi-centre test cohorts.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-02-01
DOI
https://doi.org/10.3390/diagnostics16030420
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BanglaOCT2025: A Population-Specific Fovea-Centric OCT Dataset with Self-Supervised Volumetric Restoration Using Flip-Flop Swin Transformers

Chinmay Bepery, Rameswar Debnath, Sajib Saha, Md. Emranul Islam Abir et al.
Diagnostics
Optical Coherence Tomography Applications
article

BanglaOCT2025: A Population-Specific Fovea-Centric OCT Dataset with Self-Supervised Volumetric Restoration Using Flip-Flop Swin Transformers

Chinmay Bepery, Rameswar Debnath, Sajib Saha, Md. Emranul Islam Abir, Sanjay Kumar Sarker, Md. Shafiqul Islam, G. M. Atiqur Rahaman
article en

Abstract

<b>Background:</b> Age-related macular degeneration (AMD) is a major cause of vision loss, yet publicly available Optical Coherence Tomography (OCT) datasets lack demographic diversity, particularly from South Asian populations. Existing datasets largely represent Western cohorts, limiting AI generalizability. Moreover, raw OCT volumes contain redundant spatial information and speckle noise, hindering efficient analysis. <b>Methods:</b> We introduce BanglaOCT2025, a retrospective dataset collected from the National Institute of Ophthalmology and Hospital (NIOH), Bangladesh, using Nidek RS-330 Duo 2 and RS-3000 Advance systems. We propose a novel preprocessing pipeline comprising two stages: (1) A constraint-based centroid minimization algorithm automatically localizes the foveal center and extracts a fixed 33-slice macular sub-volume, robust to retinal tilt and acquisition variability; and (2) A self-supervised volumetric denoising module based on a Flip-Flop Swin Transformer (FFSwin) backbone suppresses speckle noise without requiring paired clean reference data. <b>Results:</b> The dataset comprises 1585 OCT volumes (202,880 B-scans), including 857 expert-annotated cases (54 DryAMD, 61 WetAMD, and 742 NonAMD). Denoising quality was evaluated using reference-free volumetric metrics, paired statistical analysis, and blinded clinical review by a retinal specialist, confirming preservation of pathological biomarkers and absence of hallucination. Under a controlled paired evaluation using the same classifier with frozen weights, downstream AMD classification accuracy improved from 69.08% to 99.88%, interpreted as an upper-bound estimate of diagnostic signal recoverability rather than independent generalization. <b>Conclusions:</b> BanglaOCT2025 is the first clinically validated OCT dataset representing the Bengali population and establishes a reproducible fovea-centric volumetric preprocessing and restoration framework for AMD analysis, with future validation across independent and multi-centre test cohorts.

DiagnosticsVol. 16(3)
Khulna University (BD), Khulna Medical College (BD), Patuakhali Science and Technology University (BD), Australian e-Health Research Centre (AU), Sher-e-Bangla Agricultural University (BD)
Openalex Percentile: Top 72%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.