Assessment of whole-body and hand radiation exposure in veterinary clinic staff

Abstract Radiology is a crucial diagnostic tool used extensively in veterinary surgery as a presurgical step. The primary purpose is to obtain accurate diagnostic information to achieve a specific therapeutic effect adhering to the principle of ALARA. This research aims to estimate the dose received by the animal operating room team at the School of Veterinary Medicine at Shiraz University in Shiraz, Iran. The values for Hp (10) and Hp (0.07) were measured using thermoluminescent dosemeters (TLD), type TLD-100, for 3 months in 60 Imaging therapeutic processes of small domestic and large farm animals. The results showed that the equivalent dose to the body and hands, Hp (10) and Hp (0.07) received by the surgeon and radiology operator, is 1 ± 0.1, 1.2 ± 0.2 and 0.2 ± 0.1, and 0.39 ± 0.1 mSv, respectively. However, implementing proper radiation protection was observed, but the dose to the personnel members can be reduced.

Authors

Institutions

Publication Details

Journal
Radiation Protection and Environment
Published
2025-10-01
DOI
https://doi.org/10.4103/rpe.rpe_49_25
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of whole-body and hand radiation exposure in veterinary clinic staff

Mehdi Zehtabian, Ava ZarifSanayei, Aboutorab Tabatabai Naini, Sareh Sotoudeh
Radiation Protection and Environment
Radiation Dose and Imaging
article

Assessment of whole-body and hand radiation exposure in veterinary clinic staff

Mehdi Zehtabian, Ava ZarifSanayei, Aboutorab Tabatabai Naini, Sareh Sotoudeh
article en

Abstract

Abstract Radiology is a crucial diagnostic tool used extensively in veterinary surgery as a presurgical step. The primary purpose is to obtain accurate diagnostic information to achieve a specific therapeutic effect adhering to the principle of ALARA. This research aims to estimate the dose received by the animal operating room team at the School of Veterinary Medicine at Shiraz University in Shiraz, Iran. The values for Hp (10) and Hp (0.07) were measured using thermoluminescent dosemeters (TLD), type TLD-100, for 3 months in 60 Imaging therapeutic processes of small domestic and large farm animals. The results showed that the equivalent dose to the body and hands, Hp (10) and Hp (0.07) received by the surgeon and radiology operator, is 1 ± 0.1, 1.2 ± 0.2 and 0.2 ± 0.1, and 0.39 ± 0.1 mSv, respectively. However, implementing proper radiation protection was observed, but the dose to the personnel members can be reduced.

Radiation Protection and EnvironmentVol. 48(4)
Shiraz University (IR)
Good health and well-being
Openalex Percentile: Top 27%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.