Quick Identification of Single Open-Switch Faults in a Vienna Rectifier
Three-leg AC-DC Vienna rectifiers are susceptible to single open-switch faults, which make DC-link voltage ripple and make three-leg input AC currents distorted and unbalanced. Thus, this paper presents a quick identification method for single open-switch faults based on three-leg fault currents and output capacitors voltage difference. Fault-leg identification depended on zero-plateaus in the three-leg fault currents, whereas fault-side identification was dependent on reconstruction variables obtained through Clark transformation and phase shifting. In order to improve the reliability of the diagnosis system, the harmonic component of capacitor voltage difference is used to realize the missed diagnosis detection and adjust the time threshold automatically. This method requires no additional hardware and is easy to implement. Experimental results verify the effectiveness of this strategy. It is shown that the fault diagnosis method proposed in this paper has the advantages of fast diagnosis speed, high accuracy and good robustness.
Authors
- Fang Yao
- Qian Li
- Teng Ma
- Yue Zhao
- Xiaohui Li
Institutions
- Hebei University of Technology (CN)
- Tianjin Research Institute of Electric Science (China) (CN)
Publication Details
- Journal
- Eng—Advances in Engineering
- Published
- 2026-02-01
- DOI
- https://doi.org/10.3390/eng7020060
- Primary Topic
- Multilevel Inverters and Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Electric Power Research Institute
- State Grid Tianjin Electric Power Company