A needle in a haystack: Assessing the radiographic detectability of microsurgical suture needles using a human cadaveric model

Intraoperative loss of surgical needles represents a rare but significant challenge in operative settings, particularly in microsurgical procedures involving free tissue transfer where fine sutures (8-0 to 10-0) are employed. Current hospital protocols typically use intraoperative portable radiography to localize misplaced needles. However, the diagnostic utility of X-ray imaging in detecting small-caliber needles remains poorly defined. Following ethical approval, a cadaveric study was conducted using a range of monofilament Ethilon™ needles (3-0 to 10-0 caliber), which were inserted at four anatomically relevant surgical sites. Anteroposterior radiographs were obtained using a standard intraoperative C-arm. A total of 53 participants - including consultant surgeons, radiology trainees, nursing staff, and surgical registrars-were asked to identify needle number and location using blinded image review. Radiographic identification of needles was accurate for calibers 3-0, 4-0, 5-0, and 6-0, with identification rates approaching or exceeding 99%. Smaller needle calibers showed a dramatic decline in detection accuracy. The 8-0 needles were correctly localized in 3.77% of attempts, just one 9-0 needle was successfully identified. None of the 10-0 needles were detected across all anatomical sites. While portable radiography remains a reliable modality for locating surgical needles of caliber 3-0 to 6-0, it proves ineffective for the detection of finer microsurgical needles (≥8-0). These results have important implications for operative protocols and clinical decision-making. The routine X-ray imaging in cases of microsurgical needle loss warrants reconsideration to favor evidence-informed strategies that minimize intraoperative delays, prolonged anesthesia and unnecessary radiation exposure.

Authors

Institutions

Publication Details

Journal
JPRAS Open
Published
2026-01-30
DOI
https://doi.org/10.1016/j.jpra.2026.01.033
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A needle in a haystack: Assessing the radiographic detectability of microsurgical suture needles using a human cadaveric model

Lukas O’Brien, Shirley Potter, Barry O’Sullivan, K Reilly et al.
JPRAS Open
Surgical Sutures and Adhesives
article

A needle in a haystack: Assessing the radiographic detectability of microsurgical suture needles using a human cadaveric model

Lukas O’Brien, Shirley Potter, Barry O’Sullivan, K Reilly, Ronan A Cahill, Mary Ellen McMahon, Antonina Tcacenco
article en

Abstract

Intraoperative loss of surgical needles represents a rare but significant challenge in operative settings, particularly in microsurgical procedures involving free tissue transfer where fine sutures (8-0 to 10-0) are employed. Current hospital protocols typically use intraoperative portable radiography to localize misplaced needles. However, the diagnostic utility of X-ray imaging in detecting small-caliber needles remains poorly defined. Following ethical approval, a cadaveric study was conducted using a range of monofilament Ethilon™ needles (3-0 to 10-0 caliber), which were inserted at four anatomically relevant surgical sites. Anteroposterior radiographs were obtained using a standard intraoperative C-arm. A total of 53 participants - including consultant surgeons, radiology trainees, nursing staff, and surgical registrars-were asked to identify needle number and location using blinded image review. Radiographic identification of needles was accurate for calibers 3-0, 4-0, 5-0, and 6-0, with identification rates approaching or exceeding 99%. Smaller needle calibers showed a dramatic decline in detection accuracy. The 8-0 needles were correctly localized in 3.77% of attempts, just one 9-0 needle was successfully identified. None of the 10-0 needles were detected across all anatomical sites. While portable radiography remains a reliable modality for locating surgical needles of caliber 3-0 to 6-0, it proves ineffective for the detection of finer microsurgical needles (≥8-0). These results have important implications for operative protocols and clinical decision-making. The routine X-ray imaging in cases of microsurgical needle loss warrants reconsideration to favor evidence-informed strategies that minimize intraoperative delays, prolonged anesthesia and unnecessary radiation exposure.

JPRAS OpenVol. 48
University College Dublin (IE), Beaumont Hospital (IE), Mater Misericordiae University Hospital (IE), St. James's Hospital (IE)
Openalex Percentile: Top 71%
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.