Modeling and allocation of modern infrastructure deployment in LV European-type distribution systems for solving power quality issues

Voltage magnitude limit violations (under/over-voltage), phase unbalance and occasional conductor overloads are among the most frequent and operationally critical problems in European low-voltage (LV) distribution networks, and their incidence is rising with electrification, power-electronic loads and distributed generation. This paper proposes a DSO-oriented, operationally grounded mitigation framework that coordinates four field-ready devices: autotransformers, on-load tap changers, zigzag filters and a local power-balancing device to restore voltage compliance and reduce unbalance without relying on customer participation, advanced communications or complex power-electronic converters. To keep the assessment tractable over large historical datasets, representative stressed operating conditions are pre-selected from one year of measurements using transformer-level proxy indicators (aggregated loading and phase power disparity), removing the need for extensive power-flow simulations to a few critical cases. The methodology is validated on a standardized European LV benchmark network using real customer demand profiles and evaluated at customer connection points through voltage–magnitude and unbalance KPIs. Results show complete elimination of under-voltage occurrences, more than 95% reduction of over-voltage events, and over 98% reduction in average unbalance factor, demonstrating that coordinated deployment of established, utility-accepted devices can provide an effective and rapidly deployable operational bridge while long-term reinforcements are planned and executed. • Unified framework using four conventional devices to fix voltage issues in LV grids. • Identifies critical cases from transformer data, avoiding year-long simulations. • KPI-driven device allocation for local and system-wide power quality compliance. • Achieves 90%+ unbalance improvement and eliminates all undervoltage violations. • Validated on real Iberdrola LV network; scalable without complex power electronics.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2026-01-30
DOI
https://doi.org/10.1016/j.ijepes.2026.111632
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and allocation of modern infrastructure deployment in LV European-type distribution systems for solving power quality issues

Mesfin Fanuel, Pablo Arboleyá, Tarikua Taye, Bassam Mohamed et al.
International Journal of Electrical Power & Energy Systems
Optimal Power Flow Distribution
article

Modeling and allocation of modern infrastructure deployment in LV European-type distribution systems for solving power quality issues

Mesfin Fanuel, Pablo Arboleyá, Tarikua Taye, Bassam Mohamed, Xavier Domínguez, Jesús Gutiérrez
article en

Abstract

Voltage magnitude limit violations (under/over-voltage), phase unbalance and occasional conductor overloads are among the most frequent and operationally critical problems in European low-voltage (LV) distribution networks, and their incidence is rising with electrification, power-electronic loads and distributed generation. This paper proposes a DSO-oriented, operationally grounded mitigation framework that coordinates four field-ready devices: autotransformers, on-load tap changers, zigzag filters and a local power-balancing device to restore voltage compliance and reduce unbalance without relying on customer participation, advanced communications or complex power-electronic converters. To keep the assessment tractable over large historical datasets, representative stressed operating conditions are pre-selected from one year of measurements using transformer-level proxy indicators (aggregated loading and phase power disparity), removing the need for extensive power-flow simulations to a few critical cases. The methodology is validated on a standardized European LV benchmark network using real customer demand profiles and evaluated at customer connection points through voltage–magnitude and unbalance KPIs. Results show complete elimination of under-voltage occurrences, more than 95% reduction of over-voltage events, and over 98% reduction in average unbalance factor, demonstrating that coordinated deployment of established, utility-accepted devices can provide an effective and rapidly deployable operational bridge while long-term reinforcements are planned and executed. • Unified framework using four conventional devices to fix voltage issues in LV grids. • Identifies critical cases from transformer data, avoiding year-long simulations. • KPI-driven device allocation for local and system-wide power quality compliance. • Achieves 90%+ unbalance improvement and eliminates all undervoltage violations. • Validated on real Iberdrola LV network; scalable without complex power electronics.

International Journal of Electrical Power & Energy SystemsVol. 175
Universidad de Oviedo (ES), Iberdrola (Spain) (ES), Duro Felguera (Spain) (ES)
Industry, innovation and infrastructure
Openalex Percentile: Top 71%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.